We present the first source catalog of the Solid-state Slit Camera (SSC) of the Monitor of All-sky X-ray Image (MAXI) mission on the International Space Station, using the 45-month data from 2010 August to 2014 April in 0.7-7.0 keV bands. Sources are searched for in two energy bands, 0.7-1.85 keV (soft) and 1.85-7.0 keV (hard), the limiting sensitivity of 3 and 4 mCrab are achieved and 140 and 138 sources are detected in the soft and hard energy bands, respectively. Combining the two energy bands, 170 sources are listed in the MAXI/SSC catalog. All but 2 sources are identified with 22 galaxies including AGNs, 29 cluster of galaxies, 21 supernova remnants, 75 X-ray binaries, 8 stars, 5 isolated pulsars, and 9 non-categorized objects. Comparing the soft-band fluxes at the brightest end in our catalog with the ROSAT survey, which was performed about 20 years ago, 10% of the cataloged sources are found to have changed the flux since the ROSAT era.
X-ray CCD operated onboard satellite are contaminated by outgas from organic material used in satellites. This contamination causes a significant reduction in the detection sensitivity of X-ray detectors.In order to prevent such contamination to the Back-IlluminatedCCD (BI-CCD) of the Soft X-ray Imager (SXI) onboard ASTRO-H, we have developed a Contamination Blocking Filter (CBF), which consists of ∼30nm thick Aluminum and ∼200nm thick Polyimide. The CBF is be placed on the top of the CCD camera hood and is required to have a high X-ray transmission in order to take advantage of the high detection efficiency of BI-CCD.We measured the X-ray transmission of three fight candidates of the CBF last October at the SPring-8 and obtained the X-ray transmission of three CBFs in the soft X-ray energy from 0.2 to 1.8 keV which covers the absorption edges around C-K, N-K, O-K, and Al-K including X-ray absorption fine structure (XAFS). In these measurements, we found three CBFs have high X-ray transmission below 2ke V, e.g. ∼70% at around 0.5 keV, and determined the thickness of Al and Polyimide to be 220 nm and ∼50 nm, respectively. We will calculate the response function of SXI including these results.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.