Before disposal, radioactive sludge (Type IV) from Rocky Flats Plant (RFP) must be evaluated for volatile organic compound (VOC) content. The Type IV sludge consists of organic solvents, degreasers, cutting oils, and transuranic (TRU) waste mixed with calcium silicate (MicroCel E @) and Oil Dri@ to form a grease or pastelike material. For laboratory testing, a simulated Type N RFP sludge (nonradioactive) was prepared at Argonne National Laboratory-East. This sludge has a composition similar to that expected from field samples. On the basis of historical information, a typical Type IV sludge is expected to contain approximately 1-10 percent of three target VOCs. The objective of this work is to evaluate three proposed methods for the determination of high levels of these three VOCs in Type IV sludge. The three methods are (1) static headspace gas analysis, (2) methanol extraction, and (3) ethylene glycol extraction. All three methods employ gas chromatography/mass spectrometry (GCMS). They were evaluated regarding general method performance criteria, ease of operation, and amounts of secondary mixed waste generated.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.