Microvascular permeability to small diffusible solutes has rarely been measured at a clinical level. We have developed a simple non-invasive technique for measuring the permeability surface area (PS) product, which is suitable for clinical use. We illustrate its potential value in six subjects who underwent bone marrow transplantation for chronic myeloid leukaemia. These patients received high-dose cyclosporin A (CyA) for prevention of graft versus host disease (GVHD) and sustained an easily measurable increase in microvascular permeability to technetium 99m diethyltriamine penta-acetic acid (99mTc-DTPA). This was measured as the PS product, which increased from 1.1 (SD 0.3) to 2.2 (0.4) ml/min per 100 ml tissue between baseline and treatment with CyA for prevention of GVHD (P less than 0.01). The increase broadly correlated with nephrotoxicity which was measured, from the plasma DTPA clearance, as global glomerular filtration rate (GFR). This decreased from 106 (11.1) to 49 (6.7) ml/min (P less than 0.001). These abnormalities, both in PS product and GFR, were sustained for several months, after which they tended to return towards baseline levels. We conclude firstly that this technique has a potential clinical role and secondly that endothelial abnormalities due to CyA deserve further study.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.