-The measurement performances of in vivo monitoring vehicles were studied considering an increase in the radiological background in areas where the population is not evacuated after a nuclear accident. The study focused on 137 Cs and 131 I Detection Limits (DLs) and corresponding doses, for adults and one-year-old children. These DLs for ground contamination were obtained experimentally using a grid of point sources. Then, the DLs and doses were calculated using the experimental data and a safety factor for two accident scenarios. For these scenarios the 137 Cs DL corresponds to a committed effective dose of 0.02 mSv. The 131 I DL corresponds to committed equivalent thyroid doses of 3 mSv (adult) and 30 mSv (one-year-old child). To guarantee a 45 mSv thyroid equivalent dose assessment for the child the surface activity of 131 I + 132 I + 133 I should be below 1.6 MBq/m 2 . This study shows that the vehicles can operate in a contaminated area where the population is not evacuated. However, in such a case, the contamination level outside and inside the vehicle should be kept stable to guarantee efficient body counting.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.