An emission spectrographic method is described to determine the concentrations of aluminum, cadmium, calcium, chromium, copper, iron, lead, magnesium, nickel, silicon, tin, and zinc in airborne dirt. A measured volume of air is drawn through a 1 in. filter paper. The filter is analyzed by a direct reading emission spectrograph using a push-up technique to introduce the sample into the analytical gap. Calculations and report writing are performed by a computer. Computer programs aid the data interpretation by annotating the results and by the preparation of summaries and graphs. The precision is approximately ±25% of the amount present at the 3 µg level. Analysis time is about 5 min/sample.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.