Medication-overuse headache (MOH) is defined by the International Classification of Headache Disorders as a headache in patients with a pre-existing primary headache disorder that occurs on ≥15 days per month for >3 months, and is caused by overuse of medication intended for acute or symptomatic headache treatment. The prevalence of MOH in the general population is around 1%, but the condition is much more common in people with headache, in particular chronic migraine. The phenotype of the headache in MOH depends on the initial primary headache and the type of overused acute medication. In this Review, we will discuss the epidemiology, risk factors, pathophysiology, prevention and treatment of MOH. Treatment of MOH is performed in three steps: educating patients about the relationship between frequent intake of acute headache medication and MOH with the aim to reduce intake of acute medication; initiation of migraine prevention (such as topiramate or onabotulinumtoxin A in migraine) in patients who fail step 1; detoxification on an outpatient basis or in a day hospital or inpatient setting, depending on severity and comorbidities. The success rate of treatment is around 50-70%, although patients whose MOH is associated with opioid overuse have higher relapse rates. In all patients with MOH, relapse rates can be reduced by patient education and care in the follow-up period.
Background-Transcatheter aortic valve implantation (TAVI) is associated with a higher risk of neurological events for both the transfemoral and transapical approach than surgical valve replacement. Cerebral magnetic resonance imaging has revealed more new, albeit clinically silent lesions from procedural embolization, yet the main source and predominant procedural step of emboli remain unclear.
001).Overall, there were no significant differences between transfemoral and transapical TAVI or between the MCV and ES prostheses. No HITS were detected at baseline or 3-month follow-up. There was 1 major procedural stroke that resulted in death and 1 minor procedural stroke with full recovery at 3-month follow-up in the MCV group. Conclusions-Procedural HITS were detected by transcranial Doppler in all patients. Although no difference was observed between the transfemoral and the transapical approach with the balloon-expandable ES stent valve, transfemoral TAVI with the self-expandable MCV prosthesis resulted in the greatest number of HITS, predominantly during implantation. (Circulation. 2012;126:1245-1255.)
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.