A methodology of diagnosing the winding insulation defect according to data of transient voltage and current from the impulse voltage test is put forward in this paper. Lightning impulse test for transformer is divided into half-wave and full-wave at the moment. According to the full voltage and reduced voltage at two pressure processes. The transient voltage and current from the impulse voltage test can be divided into Series of harmonics. The insulation defect is diagnosed by dividing impulse voltage and current into series of harmonic and structuring discriminant function according to the longitudinal ratio method and cross ratio method for the corresponding period of harmonic voltage and current. The methodology is also applicable to diagnose whether there are insulation damage in the windings those have passed the lightning impulse test.
GIS is currently widely used in the power system and is the Developing Trends of Electrical appliances manufacturing. At present, a lot of research on GIS PD, but the study of the recognition of the PD severity is less. By analyzing a large number of partial discharge sample data, a new GIS PD severity diagnostic method is proposed in this paper. Partial discharge is divided into three stages (initial stage, development stage and dangerous stage) in the method according to the severity of the partial discharge. These three stages are fitted with non-linear mapping and get the fitting parameters. GIS partial discharge fault reference database can be dynamically generated with these fitting parameters. The similarity between the detected data and the reference data is discriminated with the least square method and Supplier division method, and then the GIS PD severity can be diagnosed. A large number of simulation results initially confirmed the effectiveness and feasibility of the proposed method.
Distribution transformer is an important device in the power supply system, once its failure can cause power outages. According to statistics, 70% -80% of the transformer accident was caused by a short circuit between the transformer turns. Based on the large number of experimental data analysis and processing, a new inter-turn short circuit transformer diagnostic methods is proposed. In this paper, the ground current of transformer core as the signal source, Using wavelet multi-resolution technology the signal wavelet multiscale decomposition, the decomposition of different signals of the same scale, get the high frequency components of the signal, achieve short-circuit fault diagnosis between transformer winding turns by comparing the number of the high-frequency component contained in different signals in the decomposition of the same scale. To illustrate the effectiveness of the method, the paper through a series of experiments and data processing, verify the effectiveness and feasibility of the method.
Water tree, electrical tree and electrochemical tree formed by premature defects of the cable can induce fault. The failure rate of the cable connecter which is higher than cable itself can emerge water tree, electrical tree and electrochemical tree. Meanwhile, the flashover, partial discharge and overheated of the cable joint are also the important reasons for fault. The oscillatory wave of detecting the power cable insulation defects based on is put forward in this paper in terms of the problems existed in the cable detection technology. With the application of oscillatory wave and signal source on the spot, this method dynamically generates reference database of detecting the cable insulation defects, to discriminate the fault patterns correspond to the maximum of function and detect the type, location and severity of cable insulation's defects. Water tree fault of premature cable itself and cable joint can also be detected in this method.
Power transformer is the important equipment in power system, once the occurrence of faults may bring serious harm to power grid, and even cause great losses. This paper proposes a transformer winding insulation defect detection method. The method only uses the impulse voltage test. It can obtain the diagnosis signal source which contains a lot of harmonic. This paper can judge the insulation defects in the location according to compare the extreme value distribution of every winding voltage and currents correlation coefficient .and can determine the coordinate values. The method does not need large or complex additional equipment, can realize the detection and diagnosis of transformer winding insulation defect location. It is image, intuitive, convenient and practical. This paper studies the insulation defects and the severity of transformer winding, puts forward the method for changing winding current and voltage detection winding insulation defects. And it uses a large number of experiments to verify the insulated and reliability of transformer winding according to different position, different types of insulation defects.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
customersupport@researchsolutions.com
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
This site is protected by reCAPTCHA and the Google Privacy Policy and Terms of Service apply.
Copyright © 2025 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.