In hydrogen energy systems, the polymer electrolyte fuel cell (PEFC) is an important component. The purpose of this study is to clarify the effect of separator thickness (s.t.) in PEFC on the distributions of mass such as H2, O2, H2O and current density when PEFC is operated at 363 K and 373 K. The relative humidity (RH) of supply gases also impacts the operation. The numerical simulation (using a 3D model) with COMSOL Multiphysics has been conducted to analyze the characteristics of PEFC. It has been observed that the molar concentration of H2 using s.t. of 2.0 mm is smaller compared with the thinner s.t. cases at the initial operation temperature of a cell (Tini) = 363 K and 373 K. The molar concentration of O2 using s.t. of 2.0 mm is smaller compared with the thinner s.t. cases at Tini = 373 K, as well as the case for the RH of supply gases at the anode of 40%RH and cathode of 40%RH (A40%RH/C40%RH) irrespective of Tini. Additionally, it has been clarified that the molar concentration of H2O maintains a low value along with the gas channel at Tini = 373 K using s.t. of 1.5 mm and 1.0 mm. Moreover, it has been clarified that the current density using s.t. of 2.0 mm is the highest among the different s.t. irrespective of Tini, which is the most remarkable in the case of A40%RH&C40%RH.
The aim of this study is to clarify the impact of the thickness of a gas diffusion layer (GDL) and a micro porous layer (MPL) on the distributions of gas, H2O, and current density in a polymer electrolyte fuel cell (PEFC) which is operated at 363 K and 373 K and with various thicknesses of polymer electrolyte membrane (PEM) as well as a relative humidity (RH) of supply gas. These investigations are carried out by numerical simulation using the 3D model with COMSOL Multiphysics. In the case of Nafion 115, which is the thicker PEM, the change in the molar concentration of H2O from the inlet to the outlet with MPL is larger than that without MPL irrespective of the thickness of GDL, Tini and RH condition. In the case of Nafion NRE-212, which is the thinner PEM, the change in the molar concentration of H2O from the inlet to the outlet is larger with MPL than that without MPL in the case of TGP-H-060 (the thicker commercial GDL), while that is smaller with MPL than that without MPL in the case of TGP-H-030 (the thinner commercial GDL). These results exhibit the same tendency as the results of the numerical simulation on the current density.
The New Energy and Industry Technology Development Organization (NEDO) road map (Japan, 2017) has proposed that a polymer electrolyte fuel cell (PEFC) system, which operates at a temperature of 90 °C and 100 °C, be applied for stationary and mobility usage, respectively. This study suggests using a thin polymer electrolyte membrane (PEM) and a thin gas diffusion layer (GDL), at the same time, to achieve better power-generation performance, at a higher temperature than usual. The focus of this paper is to clarify the effect of separator thickness on the distribution of temperature at the reaction surface (Treact), with the relative humidity (RH) of the supply gasses and initial operation temperature (Tini), quantitatively. In this study, separator thickness is investigated in a system using a thin PEM and a thin GDL. Moreover, this study investigates the difference between the maximum temperature and the minimum temperature obtained from the distribution of Treact as well as the relation between the standard deviation of Treact − Tini and total voltage, to clarify the effect of separator thickness. The impact of the flow rates of the supply gases on the distribution of Treact is not large, among the investigated conditions. It is noticed that the temperature distribution is wider when a separator thickness of 2.0 mm is selected. On the other hand, it is observed that the temperature increases along with the gas flow through the gas channel, by approximately 2 °C, when using a separator thickness between 1.5 mm and 1.0 mm. The impact of the RH on the distributions of Treact − Tini is larger at Tini = 100 °C, when a separator thickness of 1.0 mm is selected. It is revealed that the wider temperature distribution provides a reduction in power-generation performance. This study proposes that the thin separators, i.e., with a thickness of 1.5 mm and 1.0 mm, are not suitable for higher temperature operation than usual.
It is known from the New Energy and Industry Technology Development Organization (NEDO) roam map Japan, 2017 that the polymer electrolyte fuel cell (PEFC) power generation system is required to operate at 100˚C for application of mobility usage from 2020 to 2025. This study aims to clarify the effect of separator thickness on the distribution of the temperature of reaction surface (T react ) at the initial temperature of cell (T ini ) with flow rate, relative humidity (RH) of supply gases as well as RH of air surrounding cell of PEFC.The distribution of T react is estimated by means of the heat transfer model considering the H 2 O vapor transfer proposed by the authors. The relationship between the standard deviation of T react -T ini and total voltage obtained in the experiment is also investigated. We can know the effect of the flow rate of supply gas as well as RH of air surrounding cell of PEFC on the distribution of T react -T ini is not significant. It is observed the wider distribution of T react -T ini provides the reduction in power generation performance irrespective of separator thickness. In the case of separator thickness of 1.0 mm, the standard deviation of T react -T ini has smaller distribution range and the total voltage shows a larger variation compared to the other cases.
This study is to understand the impact of operating conditions, especially initial operation temperature (T ini ) which is set in a high temperature range, on the temperature profile of the interface between the polymer electrolyte membrane (PEM) and the catalyst layer at the cathode (i.e., the reaction surface) in a single cell of polymer electrolyte fuel cell (PEFC). A 1D multi-plate heat transfer model based on the temperature data of the separator measured using the thermograph in a power generation experiment was developed to evaluate the reaction surface temperature (T react ). In addition, to validate the proposed heat transfer model, T react obtained from the model was compared with that from the 3D numerical simulation using CFD software COMSOL Multiphysics which solves the continuity equation, Brinkman equation, Maxwell-Stefan equation, Butler-Volmer equation as well as heat transfer equation. As a result, the temperature gap between the results obtained by 1D heat transfer model and those obtained by 3D numerical simulation is below approximately 0.5 K. The simulation results show the change in the molar concentration of O 2 and H 2 O from the inlet to the outlet is more even with the increase in T ini due to the lower performance of O 2 reduction reaction. The change in the current density from the inlet to the outlet is more even with the increase in T ini and the value of current density is smaller with the increase in T ini due to the increase in ohmic over-potential and concentration over-potential. It is revealed that the change in T react from the inlet to the outlet is more even with the increase in T ini irrespective of heat transfer model.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
customersupport@researchsolutions.com
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
This site is protected by reCAPTCHA and the Google Privacy Policy and Terms of Service apply.
Copyright © 2024 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.