This study confirmed the theoretical framework of right ventricular preload and ventricular filling pressure and respiratory variation of stroke volume. The result also suggests that SVV can correctly predict preload status compared to pressure-based indices.
HES 70/0.5 exerted larger volume effects than did crystalloid under nonspecific conditions. However, similar volume effects were observed during volume loss and extensive sympathetic blockade.
Proper fluid management is crucial for the management of critically ill patients. However, there is a continuing debate about the choice of the fluid, i.e., crystalloid vs. colloid. Colloid solution is theoretically advantageous to the crystalloid because of larger volume effect and less interstitial fluid accumulation, and hydroxyethyl starch (HES) is most frequently used for perioperative setting. Nevertheless, application of HES solution is relatively limited due to its side effects including renal toxicity and coagulopathy. Since prolonged presence of large HES molecule is responsible for these side effects, rapidly degradable HES solution with low degree of substitution (tetrastarch) supposedly has less potential for negative effects. Thus, tetrastarch may be more frequently used in the ICU setting. However, several large-scale randomized trials reported that administration of tetrastarch solution to the patients with severe sepsis has negative effects on mortality and renal function. These results triggered further debate and regulatory responses around the world. This narrative review intended to describe the currently available evidence about the advantages and disadvantages of tetrastarch in the ICU setting.
The purpose of this prospective study was to evaluate the accuracy and trending ability of a four-wavelength pulse-total hemoglobinometer that continuously and noninvasively measures hemoglobin in surgical patients. With IRB approval and informed consent, spectrophotometric hemoglobin (SpHb) was measured with a pulse-total hemoglobinometer manufactured by Nihon Kohden Corp (Tokyo, Japan) and compared to the CO-oximeter equipped with blood gas analyzer. Two hundred twenty-five samples from 56 subjects underwent analysis. Bland-Altman analysis revealed that the bias ± precision of the current technology was 0.0 ± 1.4 g/dl and -0.2 ± 1.3 g/dl for total samples and samples with 8 < Hb < 11 g/dl, respectively. The percentages of samples with intermediate risk of therapeutic error in error grid analysis and the concordance rate of 4-quadrant trending assay was 17 % and 77 %, respectively. The Cohen kappa statistic for Hb < 10 g/dl was 0.38, suggesting that the agreement between SpHb and CO-oximeter-derived Hb was fair. Collectively, wide limits of agreement, especially at the critical level of hemoglobin, and less than moderate agreement against CO-oximeter-derived hemoglobin preclude the use of the pulse-total hemoglobinometer as a decision-making tool for transfusion.
Background: The volume effect of iso-oncotic colloid is supposedly larger than crystalloid, but such differences are dependent on clinical context. The purpose of this single center observational study was to compare the volume and hemodynamic effects of crystalloid solution and colloid solution during surgical manipulation in patients undergoing major abdominal surgery. Methods: Subjects undergoing abdominal surgery for malignancies with intraoperative goal-directed fluid management were enrolled in this observational study. Fluid challenges consisted with 250 ml of either bicarbonate Ringer solution, 6% hydroxyethyl starch or 5% albumin were provided to maintain optimal stroke volume index. Hematocrit derived-plasma volume and colloid osmotic pressure was determined immediately before and 30 min after the fluid challenge. Data were expressed as median (IQR) and statistically compared with Kruskal-Wallis test. Results: One hundred thirty-nine fluid challenges in 65 patients were analyzed. Bicarbonate Ringer solution, 6% hydroxyethyl starch and 5% albumin were administered in 42, 49 and 48 instances, respectively. Plasma volume increased 7.3 (3.6-10.0) % and 6.3 (1.4-8.8) % 30 min after the fluid challenge with 6% hydroxyethyl starch and 5% albumin and these values are significantly larger than the value with bicarbonate Ringer solution (1.0 (− 2.7-2.3) %) Colloid osmotic pressure increased 0.6 (0.2-1.2) mmHg after the fluid challenge with 6% hydroxyethyl starch and 0.7(0.2-1.3) mmHg with 5% albumin but decreased 0.6 (0.2-1.2) mmHg after the fluid challenge with bicarbonate Ringer solution. The area under the curve of stroke volume index after fluid challenge was significantly larger after 6% hydroxyethyl starch or 5% albumin compared to bicarbonate Ringer solution. Conclusions: Fluid challenge with 6% hydroxyethyl starch and 5% albumin showed significantly larger volume and hemodynamic effects compared to bicarbonate Ringer solution during gastrointestinal surgery.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.