Aromatherapy is the controlled use of plant essences for therapeutic purposes. Its applications are numerous (i.e., wellbeing, labour, infections, dementia, and anxiety treatment) but often they have not been scientifically validated. The aim of the present study is to review the available literature to determine if there is evidence for effectiveness of aromatherapy in surgical patients to treat anxiety and insomnia, to control pain and nausea, and to dress wound. Efficacy studies of lavender or orange and peppermint essential oils, to treat anxiety and nausea, respectively, have shown positive results. For other aspects, such as pain control, essential oils therapy has shown uncertain results. Finally, there are encouraging data for the treatment of infections, especially for tea tree oil, although current results are still inconclusive. It should also be considered that although they are, allergic reactions and toxicity can occur after oral ingestion. Therefore, while rigorous studies are being carried out, it is important that the therapeutic use of essential oils be performed in compliance with clinical safety standards.
Purpose Hip prostheses with metal-on-metal (MoM) coupling can release cobalt-chromium particles and ions. The aim of this work is to verify the correlation between particles in the synovial fluid and circulating ions. Methods Forty patients were enrolled; particles from synovial fluid were analysed by SEM-EDX (Scanning Electron Microscopy-Energy Dispersion X-rays analysis) and levels of circulating Co and Cr were assayed by ICP-MS (inductively-coupled plasma mass spectrometry). Results In 16 cases we did not find any particles in the synovial fluid and the Co level in whole blood was 0.05-4.42 ppb; in seven with few particles the blood level was 2.2-15.6 ppb; in six cases with several particles the level was 5.0-54.3 ppb; finally, in 11 cases we isolated not only Co-Cr particles, but also Cr particles with low or absent Co and in these patients the circulating level of Co was 23.8-109.6 ppb. Co in serum and Cr level both whole blood and serum have shown a similar trend to Co; the correlation between all these values and the corresponding particles is statistically significant in all cases. Conclusion Co and Cr both in serum and whole blood represents a systemic representation of the particle release at local level and can therefore be used to confirm a diagnosis and monitor the wear process of MoM articular prostheses.
Metal ion release and accumulation is considered to be a factor responsible for the high failure rates of metal-on-metal (MoM) hip implants. Numerous studies have associated the presence of these ions, besides other factors, including a hypoxia‑like response and changes in pH due to metal corrosion leading to the induction of the oxidative stress response. The aim of the present study was to verify whether, in patients with a MoM hip prosthesis, mRNA and protein expression of HMOX‑1 was modulated by the presence of metal ions and whether patients without prostheses exhibit a different expression pattern of this enzyme. The study was conducted on 22 matched pairs of patients with and without prostheses, for a total of 44 samples. Ion dosage was determined using inductively coupled plasma mass spectrometry equipped with dynamic cell reaction. HMOX‑1 gene expression was quantified by reverse transcription-quantitative polymerase chain reaction and HMOX‑1 protein expression was analyzed using an enzyme-linked immunosorbent assay. The results demonstrated that although there were significant differences in the metallic ion concentrations amongst the two groups of patients, there was no correlation between circulating levels of cobalt (Co) and chromium (Cr), and HMOX‑1 gene and protein expression. Additionally, there was no significant difference in the protein expression levels of HMOX‑1 between the two groups. In conclusion, it was demonstrated that circulating Co and Cr ions released by articular prosthetics do not induce an increase in HMOX‑1 mRNA and protein expression at least 3.5 years after the implant insertion. The present study suggests that involvement of HMOX‑1 may be excluded from future studies and suggests that other antioxidant enzymes, including superoxide dismutase, glutathione peroxidase and reductase should be investigated.
BIOLOX delta is the newest ceramic composite material of the BIOLOX family and its use in hip devices represents a good alternative to Metal-on-Metal or Metal-on-Polyethylene coupling. Some Metal-on-Metal hip devices have shown chromium and cobalt release, which promoted toxic effects. Furthermore, the ceramic composite contains trivalent chromium, even if strongly bound to the alumina lattice. The present study is aimed at detecting any 'in vivo' release of chromium ions from BIOLOX delta bearings in the blood, erythrocytes and urine of patients. Twenty patients implanted with total hip arthroplasty (THA) with BIOLOX delta-BIOLOX delta couplings and 21 subjects with no implanted prostheses were studied. Inductively coupled plasma mass spectrometry equipped with dynamic reaction cell was used for analysis. In the THA group the Cr ions values were; in blood mean 0.21 µg/l (±0.09), in serum 0.21 µg/l (±0.12), in normalized erythrocytes 0.13 µg/l (±0.09), in normalized urine 0.12 µg/g creatinine (±0.13). In the control group the Cr ions values were; in blood mean 0.22 µg/l (st dev 0.14), in serum 0.17 µg/l (±0.08), in normalized erythrocytes 0.13 µg/l (±0.11), in normalized urine 0.07 µg/g creatinine (±0.08). The Lab reference values were 0.1-5.0 µg/l for blood, 0.1-0.5 µg/l for serum, 0.14-4.58 µg/l for normalised erythrocytes and 0.05-2.2 µg/l for urine. All samples in both groups resulted in chromium levels within the normal reference range and the safety of BIOLOX delta ceramics, in terms of chromium ions release, has been demonstrated.
Recently, concerns have been raised about the potential effect of head-neck junction damage products at the local and systemic levels. Factors that may affect this damage process have not been fully established yet. This study investigated the possible correlations among head-neck junction damage level, implant design, material combination, and patient characteristics. Head-neck junctions of 148 retrieved implants were analysed, including both ceramic-on-ceramic (N = 61) and metal-on-metal (N = 87) bearings. In all cases, the male taper was made of titanium alloy. Damage was evaluated using a four-point scoring system based on damage morphology and extension. Patient age at implantation, implantation time, damage risk factor, and serum ion concentration were considered as independent potential predicting variables. The damage risk factor summarises head-neck design characteristics and junction loading condition. Junction damage correlated with both implantation time and damage factor risk when the head was made of ceramic. A poor correlation was found when the head was made of cobalt alloy. The fretting-corrosion phenomenon seemed mainly mechanically regulated, at least when cobalt alloy components were not involved. When a component was made of cobalt alloy, the role of chemical phenomena increased, likely becoming, over implantation time, the damage driving phenomena of highly stressed junctions.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
customersupport@researchsolutions.com
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
This site is protected by reCAPTCHA and the Google Privacy Policy and Terms of Service apply.
Copyright © 2024 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.