This study presents a numerical investigation into the cyclic performance of skewed special moment frame (SMF) connections that include composite concrete slabs. The study uses advanced finite element simulations to investigate the behaviour of shallow (W14×), medium (W24×) and deep (W33×) steel column sections with three levels of beam skew (10, 20 and 30 degrees) for both bare‐steel and composite (steel‐concrete) construction. To account for complex torsional boundary conditions that may affect the skewed connection response, prequalification‐type analyses were conducted considering the middle storey of a three‐storey, two‐way moment frame configuration. In the analyses, all skewed configurations achieved at least 0.04 rad of connection rotation during the cyclic loading protocol prior to a 20 % reduction in moment capacity. When a composite concrete slab was added, column twisting and column flange yielding increased at large skew angles (30 degrees) during positive moment cycles.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.