This paper compares two methods for rotor flux estimation of sensorless vector controlled squirrel-cage induction machine used in wind power applications. The compared methods are based on the integration of stator back electromotive force (back-emf) which is obtained from the machine parameters and measured voltages and currents. Rotor flux estimation based on the integration of back-emf leads to an estimation error due to dc drift and initial value problems associated with pure integrators. In order to overcome these problems, two methods for rotor flux estimation are compared in this paper. In first method the pure integrator is replaced by a low-pass filter (LPF), whereas the second method has a quadrature detector to detect the orthogonality between the estimated flux and back-emf and a PI controller to generate an appropriate compensation feedback level. Both methods are implemented into digital control system and verified on the laboratory model. The experimental setup consists of a squirrel cage induction generator connected to the grid via back-to-backconverter and the permanent magnet motor driven by industrial frequency converter and used as a wind turbine emulator. Experimental tests carried out on the induction generator connected to the grid demonstrate advantages and disadvantages of both methods.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.