We report a systematic relationship between sound-frequency tuning and sensitivity to interaural time delays for neurons in the midbrain nucleus of the inferior colliculus; neurons with relatively low best frequencies (BFs) showed response peaks at long delays, whereas neurons with relatively high BFs showed response peaks at short delays. The consequence of this relationship is that the steepest region of the function relating discharge rate to interaural time delay (ITD) fell close to midline for all neurons irrespective of BF. These data provide support for a processing of the output of coincidence detectors subserving low-frequency sound localization in which the location of a sound source is determined by the activity in two broad, hemispheric spatial channels, rather than numerous channels tuned to discrete spatial positions.
Responses to sound stimuli that humans perceive as moving were obtained for 89 neurons in the inferior colliculus (IC) of urethan-anesthetized guinea pigs. Triangular and sinusoidal interaural phase modulation (IPM), which produced dynamically varying interaural phase disparities (IPDs), was used to present stimuli with different depths, directions, centers, and rates of apparent motion. Many neurons appeared sensitive to dynamic IPDs, with responses at any given IPD depending strongly on the IPDs the stimulus had just passed through. However, it was the temporal pattern of the response, rather than the motion cues in the IPM, that determined sensitivity to features such as motion depth, direction, and center locus. IPM restricted only to the center of the IPD responsive area, evoked lower discharge rates than when the stimulus either moved through the IPD responsive area from outside, or up and down its flanks. When the stimulus was moved through the response area first in one direction and then back in the other, and the same IPDs evoked different responses, the response to the motion away from the center of the IPD responsive area was always lower than the response to the motion toward the center. When the IPD was closer at which the direction of motion reversed was to the center, the response to the following motion was lower. In no case did we find any evidence for neurons that under all conditions preferred one direction of motion to the other. We conclude that responses of IC neurons to IPM stimuli depend not on the history of stimulation, per se, but on the history of their response to stimulation, irrespective of the specific motion cues that evoke those responses. These data are consistent with the involvement of an adaptation mechanism that resides at or above the level of binaural integration. We conclude that our data provide no evidence for specialized motion detection involving dynamic IPD cues in the auditory midbrain of the mammal.
Responses of low-frequency neurons in the inferior colliculus (IC) of anesthetized guinea pigs were studied with binaural beats to assess their mean best interaural phase (BP) to a range of stimulating frequencies. Phase plots (stimulating frequency vs BP) were produced, from which measures of characteristic delay (CD) and characteristic phase (CP) for each neuron were obtained. The CD provides an estimate of the difference in travel time from each ear to coincidence-detector neurons in the brainstem. The CP indicates the mechanism underpinning the coincidence detector responses. A linear phase plot indicates a single, constant delay between the coincidence-detector inputs from the two ears. In more than half (54 of 90) of the neurons, the phase plot was not linear. We hypothesized that neurons with nonlinear phase plots received convergent input from brainstem coincidence detectors with different CDs. Presentation of a second tone with a fixed, unfavorable delay suppressed the response of one input, linearizing the phase plot and revealing other inputs to be relatively simple coincidence detectors. For some neurons with highly complex phase plots, the suppressor tone altered BP values, but did not resolve the nature of the inputs. For neurons with linear phase plots, the suppressor tone either completely abolished their responses or reduced their discharge rate with no change in BP. By selectively suppressing inputs with a second tone, we are able to reveal the nature of underlying binaural inputs to IC neurons, confirming the hypothesis that the complex phase plots of many IC neurons are a result of convergence from simple brainstem coincidence detectors.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
customersupport@researchsolutions.com
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
This site is protected by reCAPTCHA and the Google Privacy Policy and Terms of Service apply.
Copyright © 2024 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.