A validation study designed to meet the requirements of the AOAC Research Institute and the U.S. Food and Drug Administration, Center for Veterinary Medicine (FDA/CVM) was conducted for a receptor and antibody-based, immunochromatographic method (BetaStar Plus) for detection of beta-lactam antibiotic residues in raw, commingled bovine milk. The assay was found to detect amoxicillin, ampicillin, ceftiofur, cephapirin, cloxacillin, and penicillin G at levels below the FDA tolerance/safe levels, but above the maximum sensitivity thresholds established by the National Conference on Interstate Milk Shipments (NCIMS). Results of the part I (internal) and part II (independent laboratory) dose-response studies employing spiked samples were in close agreement. The test was able to detect all six drugs at the approximate 90/95% sensitivity levels when presented as incurred residues in milk collected from cows that had been treated with the specific drug. Selectivity of the assay was 100%, as no false-positive results were obtained in testing of 1031 control milk samples. Results of ruggedness experiments established the operating parameter tolerances for the BetaStar Plus assay. Results of cross-reactivity testing established that the assay detects certain other beta-lactam drugs (dicloxacillin and ticarcillin), but it does not cross-react with any of 30 drugs belonging to other classes. Abnormally high bacterial or somatic cell counts in raw milk produced no interference with the ability of the test to detect beta-lactams at tolerance/safe levels.
Neogen Corp. (Lansing, MI) has developed a common aqueous extraction method for the detection of mycotoxins in the ELISA or lateral flow format. The Veratox® for Total Aflatoxin ELISA extraction method uses a MAX 2 extraction packet and water in replacement of traditionally used organic solvents. Veratox for Total Aflatoxin has a detection range of 5-50 ppb neat or up to 300 ppb with dilution. The kit development focused on superior cross-reactivity, ability to accurately detect naturally contaminated samples, and utilization of an aqueous extraction method. In two separate validation studies, the Veratox for Total Aflatoxin test kit resulted in average yields of 91-114% in naturally contaminated mycotoxin reference material corn. The cross-reactivity profiles for aflatoxins B1, B2, G1, and G2 were 100, 113, 103, and 93%, respectively. This kit is approved by the Grain Inspection, Packers, and Stockyards Administration.
Background: The Reveal Q+ MAX for Aflatoxin is a lateral flow immunochromatographic test intended for quantitative analysis within 6 min after aqueous extraction. Objective: Work was conducted to validate the performance of the Reveal Q+ MAX for Aflatoxin method in selected corn and nut matrixes. Methods: This method was validated under the requirements of the AOAC Research Institute Performance Tested MethodSM program. Fivematrixes, including corn naturally contaminated with aflatoxin at 0, 5.2, 21.0, 51.6, 103.6, and 282 ppb as well as peanuts, pistachios, walnuts, and almonds spiked at 0, 5, 20, 50, and 300 ppb were analyzed. Results: Average percentage recoveries of the added aflatoxin from the matrixes ranged from 80.8 to 116.9%. Average LOD for all matrixes is 2 ppb and LOQ is 7 ppb. With the exceptionof sample size for almonds, robustness trials demonstrated that deliberate changes to the assay parameters minimally affected the Reveal Q+ MAX assay performance. Finally, stability results from three independently manufactured lots support Reveal Q+ MAX for Aflatoxin performance consistency and shelf-life of 18 months when stored at room temperature. Conclusions: This study appropriatelyvalidates the Performance Tested MethodSM claim forcorn and selected nut matrixes on Reveal Q+ MAX forAflatoxin, an aqueous lateral flow test kit. Highlights: Aqueous lateral flow test kit detects total aflatoxin between 80 to 120% yieldwith an LOD of 2 ppb.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
customersupport@researchsolutions.com
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
This site is protected by reCAPTCHA and the Google Privacy Policy and Terms of Service apply.
Copyright © 2024 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.