Objective: One of the factors contributing to complications related to open repair of the aorta is the construction of a hand-sewn anastomosis. Aortic anastomotic devices (AADs), such as the intraluminal ringed graft (IRG), and the anastomotic stenting technique have been developed to perform a sutureless and less complicated anastomosis. This study performed a systematic review and meta-analysis of the literature reporting clinical use of AADs and aimed to assess, primarily, the effect of each device on 30-day overall and operation-related mortality and aortic cross-clamping time and, secondarily, the rate of successful two-sided application of the IRG device and the operation-related morbidity for each device.Methods: An electronic search was performed using MEDLINE, Scopus, ScienceDirect, and Cochrane Library by two independent authors. Our exclusion criteria included studies incorporating fewer than three patients and studies reporting results solely from animals or in vitro testing, results solely from end-to-side anastomosis, and results solely from endarterectomy procedures. The last search date was February 1, 2018.Results: A total of 41 studies were identified that reported outcomes for the use of three different device types: IRG, anastomotic stenting technique, and surgical staplers. The last two types were classified together as the non-IRG group. The meta-analysis included 27 studies with 50 cohorts incorporating 1260 patients. The median age of the incorporated patients was 61.4 years (range, 51-73 years), and 68.9% were male. The operations were performed for the treatment of acute aortic dissection in 82.3%. The pooled overall 30-day mortality rate varied by device type; IRG devices had a mean rate of all-cause mortality of 9.71%, whereas non-IRG devices were associated with a significantly (I 2 ¼ 15.78%; P for Cochrane Q test < .19) lower rate of death (1.47%). The pooled mean aortic cross-clamping time was 35.83 minutes. Metaregression showed that the performance of two-sided anastomosis with the IRG device significantly decreased the aortic cross-clamping time. However, a successful two-sided ringed anastomosis was performed in approximately half of the cases.Conclusions: Taking into account that the majority of operations were performed for the treatment of acute aortic dissection, AADs had a relatively low rate of 30-day mortality. Despite the observed heterogeneity in study protocols and the small sample size in the non-IRG group, the non-IRG group presented with the lowest 30-day mortality rate. Specific device-related complications between the different device types need further investigation.
Background: Hand-sewn anastomosis is a crucial part of aortic reconstruction surgery and significantly affects its outcome. The present study presents a novel, bidirectional surgical needle aimed to improve aortic anastomosis in terms of speed and ease of use. Our objective was to assess the efficacy of the new design in comparison with the conventional needle. Methods: A series of simulations were conducted with COMSOL software in order to perform a fatigue comparative analysis between the new and the conventional needle design. Ease of penetration into a piece of polydimethylsiloxane was evaluated. Lastly, the prototype was tested under in-vitro conditions in comparison with the conventional needle. Results: Based on fatigue analysis, the new needle design improves durability, provided the two tips are equally used. The polytetrafluoroethylene coating improves penetration into the tissue by 7% to 17%, while electropolishing improves penetration up to 19%. When using the novel needle design, the average anastomotic task completion time was significantly reduced by 22% and the overall distance of hand movements was significantly reduced by 20%. Conclusions: The proposed design exhibited a shorter anastomotic time and seems promising in relation to ease of use and simplicity of the anastomotic technique it introduces.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
customersupport@researchsolutions.com
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
This site is protected by reCAPTCHA and the Google Privacy Policy and Terms of Service apply.
Copyright © 2024 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.