Background: Relative enhanced diffusivity (RED) is a potential biomarker for indirectly measuring perfusion in tissue using diffusion-weighted magnetic resonance imaging (MRI) with 3 b values. Purpose: To optimize the RED MRI protocol for the prostate, and to investigate its potential for prostate cancer (PCa) diagnosis. Study Type: Prospective. Population: Ten asymptomatic healthy volunteers and 35 patients with clinical suspicion of PCa. Sequence: 3T T 2 -and diffusion-weighted MRI with b values: b = 0, 50, [100], 150, [200], 250, [300], 400, 800 s/mm 2 (values in brackets were only used for patients). Assessment: Monte Carlo simulations were performed to assess noise sensitivity of RED as a function of intermediate b value. Volunteers were scanned 3 times to assess repeatability of RED. Patient data were used to investigate RED's potential for discriminating between biopsy-confirmed cancer and healthy tissue, and between true and false positive radiological findings. Statistical Tests: Within-subject coefficient of variation (WCV) to assess repeatability and receiver-operating characteristic curve analysis and logistic regression to assess diagnostic performance of RED. Results: The repeatability was acceptable (WCV = 0.2-0.3) for all intermediate b values tested, apart from b = 50 s/mm 2 (WCV = 0.3-0.4). The simulated RED values agreed well with the experimental data, showing that an intermediate b value between 150-250 s/mm 2 minimizes noise sensitivity in both peripheral zone (PZ) and transition zone (TZ). RED calculated with the b values 0, 150 and 800 s/mm 2 was significantly higher in tumors than in healthy tissue in both PZ (P < 0.001, area under the curve [AUC] = 0.85) and PZ + TZ (P < 0.001, AUC = 0.84). RED was shown to aid apparent diffusion coefficient (ADC) in differentiating between false-positive findings and true-positive PCa in the PZ (AUC; RED = 0.71, ADC = 0.74, RED+ADC = 0.77). Data Conclusion: RED is a repeatable biomarker that may have value for prostate cancer diagnosis. An intermediate b value in the range of 150-250 s/mm 2 minimizes the influence of noise and maximizes repeatability. Level of Evidence: 2 Technical Efficacy Stage: 1
Daniel Chen Billdal (f. 1996) er medisinstudent ved Norges teknisk-naturvitenskapelige universitet og arbeidslivsansvarlig i Norsk medisinstudentforening Trondheim. Forfatter har fylt ut ICMJE-skjemaet og oppgir ingen interessekonflikter. TURID ØKLAND Turid Økland (f. 1991) er medisinstudent ved Aarhus Universitet og arbeidslivsansvarlig i Norsk medisinstudentforening Utland. Forfatter har fylt ut ICMJE-skjemaet og oppgir ingen interessekonflikter.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
customersupport@researchsolutions.com
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
This site is protected by reCAPTCHA and the Google Privacy Policy and Terms of Service apply.
Copyright © 2024 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.