MRI is often used in tumor localization for radiotherapy treatment planning, with gadolinium (Gd)-containing materials often introduced as a contrast agent. Motexafin gadolinium is a novel radiosensitizer currently being studied in clinical trials. The nanoparticle technologies can target tumors with high concentration of high-Z materials. This Monte Carlo study is the first detailed quantitative investigation of high-Z material Gd-induced dose enhancement in megavoltage external beam photon therapy. BEAMnrc, a radiotherapy Monte Carlo simulation package, was used to calculate dose enhancement as a function of Gd concentration. Published phase space files for the TrueBeam flattening filter free (FFF) and conventional flattened 6MV photon beams were used. High dose rate (HDR) brachytherapy with Ir-192 source was also investigated as a reference. The energy spectra difference caused a dose enhancement difference between the two beams. Since the Ir-192 photons have lower energy yet, the photoelectric effect in the presence of Gd leads to even higher dose enhancement in HDR. At depth of 1.8 cm, the percent mean dose enhancement for the FFF beam was 0.38±0.12, 1.39±0.21, 2.51±0.34, 3.59±0.26, and 4.59±0.34 for Gd concentrations of 1, 5, 10, 15, and 20 mg/mL, respectively. The corresponding values for the flattened beam were 0.09±0.14, 0.50±0.28, 1.19±0.29, 1.68±0.39, and 2.34±0.24. For Ir-192 with direct contact, the enhanced were 0.50±0.14, 2.79±0.17, 5.49±0.12, 8.19±0.14, and 10.80±0.13. Gd-containing materials used in MRI as contrast agents can also potentially serve as radiosensitizers in radiotherapy. This study demonstrates that Gd can be used to enhance radiation dose in target volumes not only in HDR brachytherapy, but also in 6 MV FFF external beam radiotherapy, but higher than the currently used clinical concentration (>5 mg/mL) would be needed.
Flattening filter‐free (FFF) beams produce higher dose rates. Combined with compensator‐based intensity modulated radiotherapy (IMRT) techniques, the dose delivery for each beam can be much shorter compared to the flattened beam MLC‐based or flattened beam compensator‐based IMRT. This ‘snap shot’ IMRT delivery is beneficial to patients for tumor motion management. Due to softer energy, superficial doses in FFF beam treatment are usually higher than those from flattened beams. Due to no flattening filter, thus less photon scattering, peripheral doses are usually lower in FFF beam treatment. However, in compensator‐based IMRT using FFF beams, the compensator is in the beam pathway. Does it introduce beam hardening effects and scattering such that the superficial dose is lower and peripheral dose is higher compared to FFF beam MLC‐based IMRT? This study applied Monte Carlo techniques to investigate the superficial and peripheral doses in compensator‐based IMRT using FFF beams and compared it to the MLC‐based IMRT using FFF beams and flattened beams. Besides varying thicknesses of brass slabs to simulate varying thicknesses of compensators, a simple cone‐shaped compensator was simulated to mimic a clinical application. The dose distribution in water phantom by the cone‐shaped compensator was then simulated by multiple MLC‐defined FFF and flattened beams with varying apertures. After normalization to the maximum dose, Dmax, the superficial and peripheral doses were compared between the FFF beam compensator‐based IMRT and FFF/flattened beam MLC‐based IMRT. The superficial dose at the central 0.5 mm depth was about 1% (of Dmax) lower in the compensator‐based 6 MV FFF (6FFF) IMRT compared to the MLC‐based 6FFF IMRT, and about 8% higher than the flattened 6 MV MLC‐based IMRT dose. At 8 cm off‐axis at depth of central maximum dose, dmax, the peripheral dose between the 6FFF and flattened 6 MV MLC demonstrated similar doses, while the compensator dose was about 1% (of Dmax) higher. Compensators reduce the superficial doses slightly compared to open FFF beams, but increases the peripheral doses due to scatter in the compensator.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
customersupport@researchsolutions.com
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
This site is protected by reCAPTCHA and the Google Privacy Policy and Terms of Service apply.
Copyright © 2025 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.