The objective of this randomized, controlled trial was to assess whether voluntary participation in a proctored, proficiency-based, virtual reality robotic suturing curriculum using the da Vinci(®) Skills Simulator™ improves robotic suturing performance. Residents and attending surgeons were randomized to participation or non-participation during a 5 week training curriculum. Robotic suturing skills were evaluated before and after training using an inanimate vaginal cuff model, which participants sutured for 10 min using the da Vinci(®) Surgical System. Performances were videotaped, anonymized, and subsequently graded independently by three robotic surgeons. 27 participants were randomized. 23 of the 27 completed both the pre- and post-test, 13 in the training group and 10 in the control group. Mean training time in the intervention group was 238 ± 136 min (SD) over the 5 weeks. The primary outcome (improvement in GOALS+ score) and the secondary outcomes (improvement in GEARS, total knots, satisfactory knots, and the virtual reality suture sponge 1 task) were significantly greater in the training group than the control group in unadjusted analysis. After adjusting for lower baseline scores in the training group, improvement in the suture sponge 1 task remained significantly greater in the training group and a trend was demonstrated to greater improvement in the training group for the GOALS+ score, GEARS score, total knots, and satisfactory knots.
BackgroundMaternal heart rate artefact is a signal processing error whereby the fetal heart rate is masked by the maternal pulse, potentially leading to danger by failure to recognize an abnormal fetal heart rate or a pre-existing fetal death. Maternal heart rate artefact may be exacerbated by autocorrelation algorithms in modern fetal monitors due to smooth transitions between maternal and fetal heart rates rather than breaks in the tracing. In response, manufacturers of cardiotocography monitors recommend verifying fetal life prior to monitoring and have developed safeguards including signal ambiguity detection technologies to simultaneously and continuously monitor the maternal and fetal heart rates. However, these safeguards are not emphasized in current cardiotocography clinical practice guidelines, potentially leading to a patient safety gap.MethodsThe United States Food and Drug Administration Manufacturer and User Facility Device Experience database was reviewed for records with event type “Death” for the time period March 31, 2009 to March 31, 2019, in combination with search terms selected to capture all cases reported involving cardiotocography devices. Records were reviewed to determine whether maternal heart rate artefact was probable and/or whether the report contained a recommendation from the device manufacturer regarding maternal heart rate artefact.ResultsForty-seven cases of perinatal mortality were identified with probable maternal heart rate artefact including 14 with antepartum fetal death prior to initiation of cardiotocography, 14 with intrapartum fetal death or neonatal death after initiation of cardiotocography, and 19 where the temporal relationship between initiation of cardiotocography and death cannot be definitively established from the report. In 29 cases, there was a recommendation from the manufacturer regarding diagnosis and/or management of maternal heart rate artefact.ConclusionsThis case series indicates a recurring problem with undetected maternal heart rate artefact leading to perinatal mortality and, in cases of pre-existing fetal death, healthcare provider confusion. In response, manufacturers frequently recommend safeguards which are found in their device’s instructions for use but not in major intrapartum cardiotocography guidelines. Cardiotocography guidelines should be updated to include the latest safeguards against the risks of maternal heart rate artefact. An additional file summarizing key points for clinicians is included.
Health care team training and simulation-based education are important for preparing obstetrical services to meet the challenges of the COVID-19 pandemic. Priorities for training are identified in two key areas. First, the impact of infection prevention and control protocols on processes of care (e.g., appropriate and correct use of personal protective equipment, patient transport, preparation for emergency cesarean delivery with the potential for emergency intubation, management of simultaneous obstetric emergencies, delivery in alternate locations in the hospital, potential for increased decision-todelivery intervals, and communication with patients). And second, the effects of COVID-19 pathophysiology on obstetrical patients (e.g., testing and diagnosis, best use of modified obstetric early warning systems, approach to maternal respiratory compromise, collaboration with critical care teams, and potential need for cardiopulmonary resuscitation). However, such training is more challenging during the COVID-19 pandemic because of the requirements for social distancing. This article outlines strategies (spatial, temporal, videorecording, video-conferencing, and virtual) to effectively engage in health care team training and simulation-based education while maintaining social distancing during the COVID-19 pandemic.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
customersupport@researchsolutions.com
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
This site is protected by reCAPTCHA and the Google Privacy Policy and Terms of Service apply.
Copyright © 2024 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.