The assessment of ventricular function, cardiac chamber dimensions and ventricular mass is fundamental for clinical diagnosis, risk assessment, therapeutic decisions, and prognosis in patients with cardiac disease. Although cardiac computed tomography (CT) is a noninvasive imaging technique often used for the assessment of coronary artery disease, it can also be utilized to obtain important data about left and right ventricular function and morphology. In this review, we will discuss the clinical indications for the use of cardiac CT for ventricular analysis, review the evidence on the assessment of ventricular function compared to existing imaging modalities such cardiac MRI and echocardiography, provide a typical cardiac CT protocol for image acquisition and post-processing for ventricular analysis, and provide step-by-step instructions to acquire multiplanar cardiac views for ventricular assessment from the standard axial, coronal, and sagittal planes. Furthermore, both qualitative and quantitative assessments of ventricular function as well as sample reporting are detailed.
Purpose We sought to determine the performance of an automated computed tomography (CT) software that provides dynamic annular measurements of all available cardiac phases for transcatheter aortic valve replacement (TAVR) sizing as compared to the standard single manual measurement. Materials and Methods In 60 TAVR patients (84±7 years, 60% male) who underwent pre-procedural CT scans, we measured the aortic annular diameters, perimeter, and area using (1) the dynamic automated CT measurements and (2) standard single manual measurement from the cardiac phase of maximum systolic opening by visual estimate. Results The automated software was successful in providing annular measurements in 43/60 (72%) of cases, with the remainder requiring semi-automated contours. The maximum dynamic automated values were predominantly in systole (46/60[77%] for diameter, 44/60[73%] for perimeter, 48/60[80%] for area), and was a different phase from the standard manual phase in 46/60 (77%) cases. The maximum dynamic automated annular values were larger than the standard manual values measured (Δdiameter 0.35 mm, p=0.04; Δperimeter 1.71 mm, p<0.001; Δarea 15.6 mm2, p<0.001). When comparing standard manual to the same phase by automated measurements, while there was no difference in annular mean diameter (p=0.80), perimeter and area were larger with the automated measurements (Δperimeter 0.95 mm, p=0.002; Δarea 10.8 mm2, p=0.03). However, the maximum automated measurements were consistently larger than the same phase automated measurements (Δdiameter 0.13 mm, p<0.001; Δperimeter 0.42 mm, p<0.001; Δarea 4.4 mm2, p<0.001). Conclusions Automated maximum dynamic CT annular measurements provide larger values than standard manual and same phase automated measurements.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
customersupport@researchsolutions.com
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
This site is protected by reCAPTCHA and the Google Privacy Policy and Terms of Service apply.
Copyright © 2025 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.