Sandiness in ice-cream due to lactose crystallization can still be a problem in many circumstances. Lactose crystallization occurs in ice-cream as the unfrozen phase becomes supersaturated. However, the effects of storage temperature and temperature fluctuations on lactose crystallization have not been very well quantified. In this work, an accelerated storage apparatus was used to determine the effects of thermal fluctuations (from kO.01 "C to +2.0°C), at several mean storage temperatures (from -5.0 to -2O.O0C), on the onset of lactose nucleation and subsequent crystal growth in a standard vanilla ice-cream. The induction time for nucleation initially decreased as temperature was lowered (for temperature oscillations of +1 .O°C), until a minimum induction time of 3 h was found between -10.0 and -12.0"C. Further decreases in storage temperature caused the induction time to increase. The induction time for nucleation increased as the extent of temperature fluctuations increased, from 0.01 to 2.0°C, while initial lactose crystal growth rate showed the opposite trend. The initial growth rate increased as temperature decreased between -5.0 and -1 O.O"C, but then decreased for temperatures below -1O.O"C. At -2O.O"C lactose crystals grew very slowly. At -1 0.0"C the rate of growth decreased with increasing amplitude of temperature oscillations.
A factorial experimental design was used to study the effect of exhaust heat recovery, air flow rate and outlet temperature on the energy consumption of a spray dryer. A commercial‐scale cocurrent flow dryer with pressure atomization was used to dry 15 wt% sodium sulfate solutions. the inlet air to the dryer was preheated by using a shell‐and‐tube heat exchanger to recover energy from the exhaust air. Heat recovery reduced the energy consumption of the dryer by 12–28%, with the largest reduction occurring at the high levels of air flow rate (13,000 kg/h) and outlet temperature (104°C). the energy consumption of the dryer was lowest when heat was recovered at the low air flow rate (6500 kg/h) and low outlet temperature (82°C).
No problems were encountered with fouling or cleaning of the heat exchanger. the total pressure drop across the heat exchanger varied from 0.05–0.2 kPa depending on the air flow rate. This additional flow restriction resulted in an estimated 8% decrease in air flow rate but had negligible effect on energy consumption. the warm‐up time and the space required by the heat recovery unit were insignificant factors for this dryer. the payback period of the heat recovery system was estimated as 4.1–5.4 years with a rate of return of 21–28%.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.