Background Detection of SARS-CoV-2 antigens in blood has high sensitivity in adults with acute COVID-19, but sensitivity in pediatric patients is unclear. Recent data suggest that persistent SARS-CoV-2 spike antigenemia may contribute to multisystem inflammatory syndrome in children (MIS-C). We quantified SARS-CoV-2 nucleocapsid (N) and spike (S) antigens in blood of pediatric patients with either acute COVID-19 or MIS-C using ultrasensitive immunoassays (Meso Scale Discovery). Methods Plasma was collected from inpatients (<21 years) enrolled across 15 hospitals in 15 US states. Acute COVID-19 patients (n=36) had a range of disease severity and positive nasopharyngeal SARS-CoV-2 RT-PCR within 24 hours of blood collection. Patients with MIS-C (n=53) met CDC criteria and tested positive for SARS-CoV-2 (RT-PCR or serology). Controls were patients pre-COVID-19 (n=67) or within 24h of negative RT-PCR (n=43). Results Specificities of N and S assays were 95-97% and 100%, respectively. In acute COVID-19 patients, N/S plasma assays had 89%/64% sensitivity, respectively; sensitivity in patients with concurrent nasopharyngeal swab cycle threshold (Ct) < 35 were 93%/63%. Antigen concentrations ranged from 1.28-3,844 pg/mL (N) and 1.65-1,071 pg/mL (S) and correlated with disease severity. In MIS-C, antigens were detected in 3/53 (5.7%) samples (3 N-positive: 1.7, 1.9, 121.1 pg/mL; 1 S-positive: 2.3 pg/mL); the patient with highest N had positive nasopharyngeal RT-PCR (Ct 22.3) concurrent with blood draw. Conclusions Ultrasensitive blood SARS-CoV-2 antigen measurement has high diagnostic yield in children with acute COVID-19. Antigens were undetectable in most MIS-C patients, suggesting that persistent antigenemia is not a common contributor to MIS-C pathogenesis.
Convenient and widespread serology testing may alter the trajectory of the COVID-19 pandemic. This study seeks to leverage high-throughput, multiplexed serologic assays, which have been adopted as benchmarks for vaccine efficacy, to support large-scale surveys of SARS-CoV-2 immunity using finger-stick blood and/or saliva. Specifically, we optimized MSD’s serology assays, which were analytically validated for serum, to test self-collected finger-stick blood and saliva samples to identify prior infection. We show that these assays can be used with FDA-registered specimen collection devices to obtain quantitative measurements for self-collected samples. First, we show that salivary antibodies are stable without refrigeration or preservatives for at least 5 days. We selected classification thresholds for antibodies against SARS-CoV-2 N, RBD and Spike in finger-stick blood and saliva that provided 98% specificity in a set of individuals without known COVID-19 exposure. Using matched samples, we show that testing of saliva and finger-stick blood equivalently identified individuals with humoral responses to CoV-2 antigens. Moreover, we piloted a simple saliva collection kit that can be used to safely send samples through the mail using written instructions only. This work establishes key parameters to robustly assay self-collected finger-stick blood and saliva using quantitative immunoassays that could support large-scale serology testing.
Objectives Widespread SARS-CoV-2 testing is invaluable for identifying asymptomatic/pre-symptomatic individuals. There remains a technological gap for highly reliable, easy, and quick SARS-CoV-2 diagnostic tests suitable for frequent mass testing. Compared to nasopharyngeal (NP) swab-based tests, saliva-based methods are attractive due to easier and safer sampling. Current saliva-based SARS-CoV-2 rapid antigen tests (RATs) are hindered by limited analytical sensitivity. Here, we report one of the first ultrasensitive, saliva-based SARS-CoV-2 antigen assays with an analytical sensitivity of <0.32 pg/mL, corresponding to four viral RNA copies/µL, which is comparable to that of PCR-based tests. Methods Using the novel electrochemiluminescence (ECL)-based immunoassay, we measured the SARS-CoV-2 nucleocapsid (N) antigen concentration in 105 salivas, obtained from non-COVID-19 and COVID-19 patients. We then verified the results with a second, independent cohort of 689 patients (3.8% SARS-CoV-2 positivity rate). We also compared our method with a widely used point-of-care rapid test. Results In the first cohort, at 100% specificity, the sensitivity was 92%. Our assay correctly identified samples with viral loads up to 35 CT cycles by saliva-based PCR. Paired NP swab-based PCR results were obtained for 86 cases. Our assay showed high concordance with saliva-based and NP swab-based PCR in samples with negative (<0.32 pg/mL) and strongly positive (>2 pg/mL) N antigen concentrations. In the second cohort, at 100% specificity, sensitivity was also 92%. Our assay is about 700-fold more sensitive than the Abbott Panbio Rapid Test. Conclusions We demonstrated the ultrasensitivity and specificity assay and its concordance with PCR. This novel assay is especially valuable when compliance to frequent swabbing may be problematic.
Background: Detection of SARS-CoV-2 antigens in blood has high sensitivity in adults with acute COVID-19, but sensitivity in pediatric patients is unclear. Recent data suggest that persistent SARS-CoV-2 spike antigenemia may contribute to multisystem inflammatory syndrome in children (MIS-C). We quantified SARS-CoV-2 nucleocapsid (N) and spike (S) antigens in blood of pediatric patients with either acute COVID-19 or MIS-C using ultrasensitive immunoassays (Meso Scale Discovery). Methods: Plasma was collected from inpatients (<21 years) enrolled across 15 hospitals in 15 US states. Acute COVID-19 patients (n=36) had a range of disease severity and positive nasopharyngeal SARS-CoV-2 RT-PCR within 24 hours of blood collection. Patients with MIS-C (n=53) met CDC criteria and tested positive for SARS-CoV-2 (RT-PCR or serology). Controls were patients pre-COVID-19 (n=67) or within 24h of negative RT-PCR (n=43). Results: Specificities of N and S assays were 95-97% and 100%, respectively. In acute COVID-19 patients, N/S plasma assays had 89%/64% sensitivity, respectively; sensitivity in patients with concurrent nasopharyngeal swab cycle threshold (Ct) ≤ 35 were 93%/63%. Antigen concentrations ranged from 1.28-3,844 pg/mL (N) and 1.65-1,071 pg/mL (S) and correlated with disease severity. In MIS-C, antigens were detected in 3/53 (5.7%) samples (3 N-positive: 1.7, 1.9, 121.1 pg/mL; 1 S-positive: 2.3 pg/mL); the patient with highest N had positive nasopharyngeal RT-PCR (Ct 22.3) concurrent with blood draw. Conclusions: Ultrasensitive blood SARS-CoV-2 antigen measurement has high diagnostic yield in children with acute COVID-19. Antigens were undetectable in most MIS-C patients, suggesting that persistent antigenemia is not a common contributor to MIS-C pathogenesis.
Widespread SARS-CoV-2 testing is highly valuable for identifying asymptomatic/pre-symptomatic individuals to slow community disease transmission. However, there remains a technological gap for highly reliable, easy, and quick SARS-CoV-2 diagnostic tests that are suitable for frequent mass testing. Compared to the conventional nasopharyngeal (NP) swab-based tests, saliva-based methods are attractive due to easier and safer sampling protocols. Despite its merits in rapid turn-around-time and high throughput compared to traditional PCR-based technologies, the widespread use of saliva-based SARS-CoV-2 rapid antigen tests is hindered by limited analytical sensitivity of current methods. Here, we report the first ultrasensitive, saliva-based SARS-CoV-2 antigen assay with an analytical sensitivity of < 0.32 pg/ml, corresponding to 4 viral RNA copies/ul, which is comparable to that of PCR-based tests. Using the novel electrochemiluminescence (ECL)-based S-PLEX immunoassay, we measured the SARS-CoV-2 nucleocapsid (N) antigen concentration in 105 saliva samples obtained from non-COVID-19 and COVID-19 patients. Our assay displayed absolute specificity and high sensitivity (90.2%), where it correctly identified samples with viral loads up to 35 CT cycles by saliva-based PCR. Paired NP swab-based PCR results were also obtained for 86 cases for comparison. Our assay showed high concordance with saliva-based and NP swab-based PCR in samples with negative (< 0.32 pg/ml) and strongly positive (> 2 pg/ml) N antigen concentrations. Our study unveiled the ultrasensitivity and specificity of the saliva-based S-PLEX assay, demonstrating its clinical value as a high throughput, complementary alternative to PCR-based techniques. The novel technique is especially valuable in cases where compliance to frequent swabbing may be problematic (e.g. schools, nursing homes, etc.).
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
customersupport@researchsolutions.com
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
This site is protected by reCAPTCHA and the Google Privacy Policy and Terms of Service apply.
Copyright © 2025 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.