The fetal ECG derived from abdominal leads provides an alternative to standard means of fetal monitoring. Furthermore, it permits long-term and ambulant recordings, which expands the range diagnostic possibilities for evaluating the fetal health state. However, due to the temporal and spectral overlap of maternal and fetal signals, the usage of abdominal leads imposes the need for elaborated signal processing routines.In this work a modular combination of processing techniques is presented. Its core consists of two maternal ECG estimation techniques, namely the extended Kalman smoother (EKS) and template adaption (TA) in combination with an innovative detection algorithm. Our detection method employs principles of evolutionary computing to detect fetal peaks by considering the periodicity and morphological characteristics of the fetal signal. In a postprocessing phase, single channel detections are combined by means of kernel density estimation and heart rate correction.The described methodology was presented during the Computing in Cardiology Challenge 2013. The entry was the winner of the closed-source events with average scores for events 4/5 with 15.1/3.32 (TA) and 69.5/4.58 (EKS) on training set-A and 20.4/4.57 (TA) and 219/7.69 (EKS) on test set-B, respectively. Using our own clinical data (24 subjects each 20 min recordings) and statistical measures beyond the Challenge's scoring system, we further validated the proposed method. For our clinical data we obtained an average detection rate of 82.8% (TA) and 83.4% (EKS). The achieved results show that the proposed methods are able produce reliable fetal heart rate estimates from a restricted number of abdominal leads.
Over the last few years, the contactless acquisition of cardiovascular parameters using cameras has gained immense attention. The technique provides an optical means to acquire cardiovascular information in a very convenient way. This review provides an overview on the technique's background and current realizations. Besides giving detailed information on the most widespread application of the technique, namely the contactless acquisition of heart rate, we outline further concepts and we critically discuss the current state.
Cardiac ejection is detectable by cbPPG under pathophysiologic conditions of cardiovascular disease and perioperative medicine. cbPPG measurements can be seamlessly integrated into the clinical work flow of critical care patients.
BackgroundCamera-based photoplethysmography (cbPPG) is a measurement technique which enables remote vital sign monitoring by using cameras. To obtain valid plethysmograms, proper regions of interest (ROIs) have to be selected in the video data. Most automated selection methods rely on specific spatial or temporal features limiting a broader application. In this work, we present a new method which overcomes those drawbacks and, therefore, allows cbPPG to be applied in an intraoperative environment.MethodsWe recorded 41 patients during surgery using an RGB and a near-infrared (NIR) camera. A Bayesian skin classifier was employed to detect suitable regions, and a level set segmentation approach to define and track ROIs based on spatial homogeneity.ResultsThe results show stable and homogeneously illuminated ROIs. We further evaluated their quality with regards to extracted cbPPG signals. The green channel provided the best results where heart rates could be correctly estimated in 95.6% of cases. The NIR channel yielded the highest contribution in compensating false estimations.ConclusionsThe proposed method proved that cbPPG is applicable in intraoperative environments. It can be easily transferred to other settings regardless of which body site is considered.Electronic supplementary materialThe online version of this article (10.1186/s12938-018-0467-7) contains supplementary material, which is available to authorized users.
Blind source separation (BSS) aims at separating useful signal content from distortions. In the contactless acquisition of vital signs by means of the camera-based photoplethysmogram (cbPPG), BSS has evolved the most widely used approach to extract the cardiac pulse. Despite its frequent application, there is no consensus about the optimal usage of BSS and its general benefit. This contribution investigates the performance of BSS to enhance the cardiac pulse from cbPPGs in dependency to varying input data characteristics. The BSS input conditions are controlled by an automated spatial preselection routine of regions of interest. Input data of different characteristics (wavelength, dominant frequency, and signal quality) from 18 postoperative cardiovascular patients are processed with standard BSS techniques, namely principal component analysis (PCA) and independent component analysis (ICA). The effect of BSS is assessed by the spectral signal-to-noise ratio (SNR) of the cardiac pulse. The preselection of cbPPGs, appears beneficial providing higher SNR compared to standard cbPPGs. Both, PCA and ICA yielded better outcomes by using monochrome inputs (green wavelength) instead of inputs of different wavelengths. PCA outperforms ICA for more homogeneous input signals. Moreover, for high input SNR, the application of ICA using standard contrast is likely to decrease the SNR.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
customersupport@researchsolutions.com
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
This site is protected by reCAPTCHA and the Google Privacy Policy and Terms of Service apply.
Copyright © 2024 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.