Introduction: Radiotherapy alone or combined with surgery and/or chemotherapy is being investigated in the treatment of malignant pleural mesothelioma (MPM). This study aimed to simulate a Volumetric Modulated Arc Therapy (VMAT) treatment of a patient with MPM. Materials and Methods: CT images from a patient with intact lungs were imported via DICOM into the Pinnacle 3 treatment planning (TP) system (TPS) and used as a model for MPM to delineate organs at risk (OAR) and both clinical and planning target volumes (CTV and PTV) with a margin of 5 mm. Elekta Synergy with 6 MV photons and 80 leafs MLCi2 was employed. VMAT plans were generated using two coplanar arcs with gantry rotation angles of 178˚-182˚, the collimator angles of each arc were set to 90˚, Octavius ® 4D 729 was employed for quality assurance while the calculated and measured doses were compared using VeriSoft. Results: A TP was achieved. The Gamma volume analysis with criteria of 3 mm distance to agreement and 3% dose difference yielded the gamma passing rate = 99.9%. The reference isodose was 42.75 Gy with the coverage constraints for the PTV D95 and V95 = 95.0% of 45 Gy. The remaining dosimetric parameters met the recommendations from the clinically acceptable guidelines for the radiotherapy of MPM. Conclusion: Using well-defined TV and VMAT, a consistent TP compared to similar ones from publications was achieved. We obtained a high agreement between the 3D dose reconstructed and the dose calculated.
Summary Aim: One of the main arguments against the acceptance and introduction of FDG PET as a regular benefit in the statutory Medical Insurance system in Germany are its (alleged) high costs. The aim of the present study has been to determine empirically over a period of twelve months the costs of FDG PET, making use of a satellite concept. Methods: Documentation on performance and consumption data has been assembled for purposes of cost analysis. After analysis these data provided the basis for an assessment of the costs. In view of the high proportion of fixed overheads and strong fluctuations in consumption values, it was not possible to allocate reliably in an individual FDG PET investigation the various types of costs to individual causes. A monthly cost assessment procedure was therefore adopted. For this purpose data were recorded in the department for Nuclear Medicine, while the statistical assessment of the consumption data and analysis of the costs were undertaken in the Institute of Industrial and Hospital Management. Results: Over the twelve month observation period (November 1995 to October 1996, 177 working days) 433 patients were included in the study: 244 with brain diseases 37 cardiac patients, 130 whole body studies and 22 combined studies (brain and whole body scans). The non volume based costs, maintenance charges and depreciation accounted for the highest proportion of the total costs (48%). The FDG- related costs accounted for 41 % of the total costs, while the personnel costs amounted to 11% and the film costs to only 0.45%. The total costs incurred amounted to DM 1,205,050. Conclusion: These data represent a first empirical cost analysis for FDG PET based on a satellite concept and form a starting point for a cost/benefit analysis of this procedure.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
customersupport@researchsolutions.com
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
This site is protected by reCAPTCHA and the Google Privacy Policy and Terms of Service apply.
Copyright © 2024 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.