This study presents an evaluation of the extent of differences between measurements performed by O(3) and NO(2) diffusive samplers and by the reference methods for diffusive samplers commercially available. The tests were performed in an exposure chamber under extreme conditions of controlling factors and under field conditions. For NO(2), the results of the laboratory experiments showed that most of the diffusive samplers were affected by extreme exposure conditions. The agreement between the samplers and the reference method was better for the field tests than for the laboratory ones. The estimate of the uptake rate for the exposure conditions using a model equation improved the agreement between the diffusive samplers and the reference methods. The agreement between O(3) measured by the diffusive samplers and by the reference method was satisfactory for 1-week exposure. For 8-hour exposures, the diffusive samplers with high uptake rates quantified better the O(3) concentration than the samplers with low uptake rates. As for NO(2), the results of the O(3) field tests were in better agreement with the reference method than the ones of the laboratory tests. The field tests showed that the majority of diffusive samplers fulfils the 25% uncertainty requirement of the NO(2) European Directive and the 30% uncertainty requirement of the O(3) European Directive for 1-week exposure.
The influence of environmental parameters on the uptake rate of the nitrogen dioxide (NO(2)) Palmes diffusive sampler was investigated. The main factors affecting the uptake rate were found to be wind speed, the preponderant factor, followed by relative humidity and temperature. The NO(2) concentration and exposure time, as well as the interactions among the factors were not found to have a significant influence on the uptake rate of the Palmes sampler. As a result, a model able to predict the uptake rate of the Palmes sampler was established. In addition, by using the model-predicted uptake rate, the agreement between chemiluminescence and the Palmes sampler during the field tests was improved. The NO(2) Palmes diffusive sampler was shown to comply with the requirement on accuracy defined by the European Directive for the indicative methods of measurements.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.