Translabial ultrasound (TLUS) is an inexpensive, noninvasive imaging modality traditionally used for assessment of pelvic organ prolapse. The utility of TLUS has recently been expanded to the evaluation of synthetic midurethral slings (MUS) surgically implanted for management of stress urinary incontinence. The purpose of this article is to familiarize radiologists with translabial ultrasound technique and provide a technical protocol for TLUS execution because it can be optimized for imaging and assessment of MUS, including identification of MUS configuration and recognition of common complications. This article provides example images of transobturator and retropubic slings and their associated complications, as visualized on TLUS. Accurate imaging and assessment of MUS is helpful in the evaluation of the patient presenting with symptoms suspicious for sling-related complications and in the planning of surgical revision.
Midurethral sling (MUS) surgical procedures, in which a polypropylene synthetic mesh graft is transvaginally placed to support the urethra and manage stress urinary incontinence (SUI), is commonly performed (Urology. 2013;82(1):38-41; Radiology. 2018;289(3):728-729). Within 10 years of sling placement, about 1 in 20 women undergo subsequent surgery to revise their mesh, in which the mesh is cut or partially excised (Obstet Gynecol. 2019;133:1099-1108. Translabial ultrasound (TLUS) has been described as a sensitive technique for viewing MUS, although few studies have evaluated its ability to view surgically revised MUS (Radiology. 2018;289(3):721-727). Understanding the anatomy of the MUS is critical to urologists and urogynecologists striving to optimize management of patients presenting with lower urinary tract symptoms and history of MUS. To assess the clinical utility and reliability of TLUS as a diagnostic tool in its detection of MUS discontinuity, we conducted a retrospective analysis on patients who underwent TLUS at a tertiary care center between September 2017 and May 2020 for indication of lower urinary tract symptoms and history of MUS placement. Performance of TLUS was evaluated by comparing findings with operative or clinical records. Among the 81 women included, detection of MUS revision, which was defined as a discontinuity in sling material, had a sensitivity of 84.6% and specificity of 97.1%. Translabial ultrasound is an inexpensive, nonirradiating, and noninvasive modality that is effective at visualizing MUSs. It is a reliable identifier of previous MUS revision, in which it detects a midline discontinuity of the hyperechoic mesh with an average 10 mm gap.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
customersupport@researchsolutions.com
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
This site is protected by reCAPTCHA and the Google Privacy Policy and Terms of Service apply.
Copyright © 2025 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.