Purpose
To optimize the direct production of 68Ga on a cyclotron, via the 68Zn(p,n)68Ga reaction using a liquid cyclotron target. We Investigated the yield of cyclotron-produced 68Ga, extraction of [68Ga]GaCl3 and subsequent [68Ga]Ga-PSMA-11 labeling using an automated synthesis module.
Methods
Irradiations of a 1.0 M solution of [68Zn]Zn(NO3)2 in dilute (0.2–0.3 M) HNO3 were conducted using GE PETtrace cyclotrons and GE 68Ga liquid targets. The proton beam energy was degraded to a nominal 14.3 MeV to minimize the co-production of 67Ga through the 68Zn(p,2n)67Ga reaction without unduly compromising 68Ga yields. We also evaluated the effects of varying beam times (50–75 min) and beam currents (27–40 μA). Crude 68Ga production was measured. The extraction of [68Ga]GaCl3 was performed using a 2 column solid phase method on the GE FASTlab Developer platform. Extracted [68Ga]GaCl3 was used to label [68Ga]Ga-PSMA-11 that was intended for clinical use.
Results
The decay corrected yield of 68Ga at EOB was typically > 3.7 GBq (100 mCi) for a 60 min beam, with irradiations of [68Zn]Zn(NO3)2 at 0.3 M HNO3. Target/chemistry performance was more consistent when compared with 0.2 M HNO3. Radionuclidic purity of 68Ga was typically > 99.8% at EOB and met the requirements specified in the European Pharmacopoeia (< 2% combined 66/67Ga) for a practical clinical product shelf-life. The activity yield of [68Ga]GaCl3 was typically > 50% (~ 1.85 GBq, 50 mCi); yields improved as processes were optimized. Labeling yields for [68Ga]Ga-PSMA-11 were near quantitative (~ 1.67 GBq, 45 mCi) at EOS. Cyclotron produced [68Ga]Ga-PSMA-11 underwent full quality control, stability and sterility testing, and was implemented for human use at the University of Michigan as an Investigational New Drug through the US FDA and also at the Royal Prince Alfred Hospital (RPA).
Conclusion
Direct cyclotron irradiation of a liquid target provides clinically relevant quantities of [68Ga]Ga-PSMA-11 and is a viable alternative to traditional 68Ge/68Ga generators.
Despite the important role of cannabinoid CB1 receptors (CB1R) in brain development, little is known about their status during adolescence, a critical period for both the development of psychosis and for initiation to substance abuse. In the present study, we assessed the ontogeny of CB1R in adolescent and adult rats in vivo using positron emission tomography with [18F]MK-9470. Analysis of covariance (ANCOVA) to control for body weight that would potentially influence [18F]MK-9470 values between the two groups revealed a main effect of age (F(1,109)=5.0, P = 0.02) on [18F]MK-9470 absolute binding (calculated as percentage of injected dose) with adult estimated marginal means being higher compared to adolescents amongst 11 brain regions. This finding was confirmed using in vitro autoradiography with [3H]CP55,940 (F(10,99)=140.1, P < 0.0001). This ontogenetic pattern, suggesting increase of CB1R during the transition from adolescence to adulthood, is the opposite of most other neuroreceptor systems undergoing pruning during this period.
2-{2-[4-(4-[18F]-Fluorobenzyl)piperazin-1-yl]-2-oxoethyl}isoindolin-1-one ([18F]MEL054), is a new potent indolinone-based melanin binder designed to target melanotic tumours. [18F]MEL054 was prepared by an automated two-step radiosynthesis, comprising of the preparation of 4-[18F]fluorobenzaldehyde from 4-formyl-N,N,N-trimethylanilinium triflate, followed by reductive alkylation with 2-(2-oxo-2-piperazin-1-ylethyl)isoindolin-1-one. 4-[18F]Fluorobenzaldehyde was prepared on a GE TRACERlab FXFN module in 68 ± 8 % radiochemical yield (RCY, non-decay corrected), purified by a Sep-Pak Plus C18 cartridge and eluted into the reactor of an in-house modified Nuclear Interface [18F]FDG synthesis module for the subsequent reductive alkylation reaction. HPLC purification produced [18F]MEL054 in a collected RCY of 34 ± 9 % (non-decay corrected), the total preparation time (including Sep-Pak Plus C18 and HPLC purification) did not exceed 105 min. The radiochemical purity of [18F]MEL054 was greater than 99 % with a specific radioactivity of 71–119 GBq μmol–1 and [18F]MEL054 remained stable in saline solution (>98 %) after 3 h.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.