Background Raman spectroscopy has gained popularity to monitor multiple process indicators simultaneously in biopharmaceutical processes. However, robust and specific model calibration remains a challenge due to insufficient analyte variability to train the models and high cross‐correlation of various media components and artifacts throughout the process. Main Methods A systematic Raman calibration workflow for perfusion processes enabling highly specific and fast model calibration was developed. Harvest libraries consisting of frozen harvest samples from multiple CHO cell culture bioreactors collected at different process times were established. Model calibration was subsequently performed in an offline setup using a flow cell by spiking process harvest with glucose, raffinose, galactose, mannose, and fructose. Major Results In a screening phase, Raman spectroscopy was proven capable not only to distinguish sugars with similar chemical structures in perfusion harvest but also to quantify them independently in process‐relevant concentrations. In a second phase, a robust and highly specific calibration model for simultaneous glucose (root mean square error prediction [RMSEP] = 0.32 g L−1) and raffinose (RMSEP = 0.17 g L−1) real‐time monitoring was generated and verified in a third phase during a perfusion process. Implication The proposed novel offline calibration workflow allowed proper Raman peak decoupling, reduced calibration time from months down to days, and can be applied to other analytes of interest including lactate, ammonia, amino acids, or product titer.
Raman spectroscopy has gained popularity to monitor multiple process indicators simultaneously in biopharmaceutical processes. However, robust and specific model calibration remains a challenge due to insufficient analyte variability to train the models and high cross-correlation of various media components and artefacts throughout the process. Therefore, a systematic Raman calibration workflow for perfusion processes enabling highly specific and fast model calibration was developed. A harvest library consisting of frozen harvest samples from multiple CHO cell culture bioreactors collected at different process times was established, capturing process variability as widely as possible. Model calibration was subsequently performed in an offline setup using a flow cell by spiking process harvest with various sugars known to modulate glycosylation patterns of monoclonal antibodies. In a screening phase, Raman spectroscopy was proven capable not only to distinguish glucose, raffinose, galactose, mannose, and fructose in perfusion harvest, but also to quantify them independently in process relevant concentrations. In a second phase, a robust and highly specific calibration model for simultaneous glucose (RMSEP = 0.32 g/L) and raffinose (RMSEP = 0.17 g/L) real-time monitoring was generated and verified in a third phase during a perfusion process. The proposed offline calibration workflow allowed proper Raman peak decoupling, reduced calibration time from months down to days and can potentially be applied to other analytes of interest including lactate, ammonia, amino acids, or product titer.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
customersupport@researchsolutions.com
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
This site is protected by reCAPTCHA and the Google Privacy Policy and Terms of Service apply.
Copyright © 2024 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.