Both techniques, NPDS and PT, without enhancements (ie, implants or antimetabolites) control IOP efficaciously at our end point. Phacoemulsification combined with penetrating and non-penetrating procedures does not seem to interfere with final results. When a lower target IOP and probability of success over time are considered, PT, single or combined, exhibits a better trend. PT, therefore, could be more suitable for higher IOP levels or longer life expectancies.
Purpose: To test the expanded polytetrafluoroethylene (ePTFE) as a new adju-vant in trabeculectomy. Methods: Consecutive glaucoma surgical inpatients were observed at the Department of Ophthalmology of Palermo University. Sixty patients (60 eyes) were randomly assigned to undergo trabeculectomy (T), trabeculectomy with mitomycin-C (TMMC), with ePTFE (TG) or with mitomycin-C and ePTFE (TGMMC). Postoperative visits were scheduled at 24 hr, 7 days, 1, 3, 6, 12, 18 and 24 months. Complete success and qualified success were assessed at two target intraocular pressure (IOP) levels-£21 and £17 mmHg-by Kaplan-Meier curves. Results: The postoperative IOP reduction was significant (P < 0.01) at the endpoint in all groups, with a mean IOP of 16.9 (±2.9), 16.2 (±2.7), 15.3 (±3.4) and 15.2 (±4.3) mmHg in T, TMMC, TG and TGMMC eyes, respectively. No intergroup difference was found at either IOP targets. The Kaplan-Meier curves relating to either the £21 mmHg or the £17 mmHg target IOP did not show significant intergroup differences for complete and qualified success rate. When ePTFE was used, a trend favouring the medium-term survival rate was noted. No adverse reaction to the ePTFE was present, and no membrane extrusion or conjuctival erosion were noted in any cases. Hypo-tony was significantly more frequent (P = 0.035) in groups without ePTFE. Moreover, the late MMC-related complications were more frequent when MMC was applied. Conclusion: Expanded polytetrafluoroethylene implant in trabeculectomy is well tolerated and could act as a filtration modulating device. Therefore, it is useful in reducing early hypotony-related complications and contributes to attaining medium-term IOP control that is comparable to the low-dosage MMC.
Acromegaly is characterized by greater CCT values, supporting the hypothesis that GH excess may have stimulatory effects on the cornea as well as on other target organs. Higher GH levels, disease control status and duration of active disease seem to be the main causes of increased corneal thickness. We suggest a careful and detailed corneal evaluation in acromegalic patients to prevent the potential risk of increased IOP, in addition to the already-known complications.
Phacoemulsification using a no-stitch, temporal, 5.2 mm clear corneal incision produced results comparable to those using a corneoscleral superior approach. A longer study of a larger series should be done to confirm the findings.
Purpose To evaluate the adequacy of common disinfection regimens for disposable tonometer tips and assess if disinfection of reusable prisms or the use of disposable tips is preferable. Methods We used disposable tonometer tips, using the same material and tip diameter of standard Goldmann tonometer prism. Strains of Pseudomonas aeruginosa, Staphylococcus aureus, Bacillus subtilis and Candida albicans were tested according to the European standard guidelines for disinfectants test. Antimicrobial effectiveness of the following disinfection practices has been assessed: dry wipe, Minuten wipes (Alpro s ), soaking in 3% hydrogen peroxide, 0.5% benzalkonium chloride, and 0.5% Pantasept s for 1, 5, and 15 min. All tests have been performed three times and all conditions tested in duplicate.Results Dry wiping and 1 min soak in 3% hydrogen peroxide were ineffective on all microrganisms. Minuten wipes, 1 min soak in 0.5% benzalkonium chloride or 3% hydrogen peroxide were ineffective on B. subtilis. 0.5% Pantasept s soak was effective in 1 min for all microrganisms tested, whereas 3% hydrogen peroxide and 0.5% benzalkonium chloride soaks were effective when performed for at least 5 min. B. subtilis was the most resistant organism to disinfectant regimes at 1 min time.Conclusions Results of our study demonstrate a relative disinfection efficacy for the different evaluated regimens, provided that correct exposure times are adopted for the chosen disinfectants, a condition difficult to ensure in a busy clinic setting. We conclude that disposable prism tonometry provides a safe alternative to Goldmann tonometry.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
customersupport@researchsolutions.com
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
This site is protected by reCAPTCHA and the Google Privacy Policy and Terms of Service apply.
Copyright © 2024 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.