Background: Baclofen commonly is used to manage spasticity caused by central nervous system lesions or dysfunction. Although both intrathecal and oral delivery routes are possible, no study has directly compared clinical outcomes associated with these 2 routes of treatment. Objective: To compare spasticity levels, pain, sleep, fatigue, and quality of life between individuals receiving treatment with intrathecal versus oral baclofen. Design: Cross-sectional matched cohort survey study. Setting: Urban academic rehabilitation outpatient clinics. Participants: Adult patients with spasticity, treated with intrathecal or oral baclofen for at least 1 year, matched 1:1 for age, gender, and diagnosis. Methods: Standardized surveys were administered during clinic appointments or by telephone. Main Outcome Measures: Surveys included the Penn Spasm Frequency Scale, Brief Pain Inventory, Epworth Sleepiness Scale, Fatigue Severity Scale, Life Satisfaction Questionnaire, and Diener Satisfaction with Life Scale. Results: A total of 62 matched subjects were enrolled. The mean (standard deviation [SD]) age was 46 (11) years with a mean duration of intrathecal baclofen or oral baclofen treatment of 11 (6) and 13 (11) years, respectively. There were 40 (64%) male and 22 (36%) female subjects. Primary diagnoses included spinal cord injury (n ¼ 38), cerebral palsy (n ¼ 10), stroke (n ¼ 10), and multiple sclerosis (n ¼ 4). The mean (SD) dose of intrathecal and oral baclofen at the time of survey were 577 (1429) mg/day and 86 (50) spasms, respectively as measured by the Penn Spasm Frequency Scale (P < .01; P < .01). There were no significant differences in pain, sleep, fatigue, and quality of life between groups. Subanalysis of patients with SCI mirrored results of the entire study sample, with significant decreases in spasm frequency and severity associated with intrathecal compared to oral baclofen (P < .01; P < .01), but no other between group differences. The mean (SD) percent change in dose of oral (21% [33%]) compared with intrathecal (3% [28%]) baclofen was significantly larger two years prior to the date of survey (P ¼ .02). Conclusions: Long-term treatment with intrathecal compared with oral baclofen is associated with reduced spasm frequency and severity as well as greater dose stability. These benefits must be weighed against the risks of internal pump and catheter placement in patients considering intrathecal baclofen therapy.
Objective Digital subtraction imaging (DSI) decreases the risk of intravascular injection during cervical transforaminal epidural steroid injection (CTFESI); however, sequence acquisition and interpretation are operator-dependent skills. This study tests the reliability of a grading system to determine adequate DSI during CTFESI. Setting Academic tertiary medical center. Methods A grading scheme for adequate DSI quality during CTFESI was created by the study authors based on patient positioning, mask image, and volume of contrast injected. The inter-rater and intrarater reliability values of this grading scheme were tested using 50 DSI images evaluated by three raters during two distinct sessions separated by four weeks. Based on a power analysis, a sample of 50 scans was sufficient to detect significant correlations. Inter-rater reliability was determined by percent agreement between graders for dichotomized categories of “quality of DSI is adequate for safe C-TFESI” vs “quality of DSI is inadequate for safe C-TFESI.” The percentage of agreement was reported, along with Gwet’s agreement coefficient (AC). The intrarater (pre/post) correlation was assessed using Yule’s Q statistics. Results Correlation coefficients were interpreted as follows: 0.00–0.19 “very weak,” 0.20–0.39 “weak,” 0.40–0.59 “moderate,” 0.60–0.79 “strong,” and 0.80–1.00 “very strong.” Inter-rater reliability analyses demonstrated that the patient position category had “very strong” agreement, contrast volume had “strong” agreement, and mask image had “moderate” agreement. The overall inter-rater reliability was “moderate.” All of the raters demonstrated “very strong” intrarater reliability. Conclusions The proposed grading system for adequate-quality DSI during CTFESI showed overall “moderate” and “very strong” inter- and intrarater reliability, respectively. This scheme provides an objective measure of DSI quality for CTFESI. Refinement is needed to improve the reliability of this scheme.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
customersupport@researchsolutions.com
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
This site is protected by reCAPTCHA and the Google Privacy Policy and Terms of Service apply.
Copyright © 2025 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.