Infliximab, a chimeric monoclonal antibody, has profoundly modified the treatment of several inflammatory diseases, but no satisfactory description of its pharmacokinetics is available. The objective of this study is to describe the pharmacokinetics of infliximab and to explore the sources of its interindividual variability. Thirty-three chronic inflammatory bowel disease patients were studied. Infliximab serum concentrations, obtained during therapeutic drug monitoring, were analyzed using a population approach. Influence of sex, weight, age, concomitant immunosuppressive treatment, and development of antibodies toward infliximab (ATI) on pharmacokinetic parameters was investigated. A two-compartment model with first-order distribution and elimination constants allowed a satisfactory description of infliximab serum concentrations. Mean population distribution and elimination half-lives were 4.3 and 18.5 days, respectively. Weight and sex were found to significantly influence volume of distribution of the central compartment, which increased with weight and was higher in men. Clearance was 2.7 times higher, and elimination half-life was 34% lower in the presence of ATI. In two patients, an increase in infliximab dose or a decrease in dosing interval lead to a decrease in infliximab clearance toward its value in patients without ATI. Infliximab pharmacokinetics are similar to those of other monoclonal antibodies, notably with an elimination half-life of approximately 3 weeks. Both body weight and sex were found to influence infliximab pharmacokinetics, and its clearance increased thrice in the presence of ATI.
SummaryThe performances of nine commercial kits and an in-house method (HM) for the quantitation of anticardiolipin antibodies (ACA) have been evaluated in a multicenter study. Ninety control and patient samples and six standards from Louisville University were run with kits and with the HM. Marked differences in positivity rate between kits were observed, ranging from 31 to 60% for IgG and 6 to 50% for IgM. Concordance between kits occurred in 59 and 51% of samples for IgG and IgM respectively. Concordance coefficients (kappa) ranged from 0.13 to 0.92. Slopes of regression lines between the declared units of Louisville standards and the units measured from the calibrators of the kits showed great diversity and ranged from 0.159 to 0.931 for IgG and from 0.236 to 0.836 for IgM. The β2-glycoprotein I (β2-GPI) content of the dilution buffers and the wells supplied with the kits revealed noticeable differences. However samples containing anti-(β2-GPI antibodies were classified similarly by all but one kit. In contrast the ability to measure samples devoid of anti-β2-GPI antibodies differed markedly between the kits.This study shows that differences in positivity rates between the commercial kits may contribute to the differences in ACA prevalence rate found in the literature. The choice of cut-off levels may partly explain the moderate concordance between the kits. In addition some samples behave very differently depending on the kits. In spite of the expression of results in PL units, standardization of ACA assays has not been achieved.
The annual cost of eculizumab maintenance therapy in paroxysmal nocturnal hemoglobinuria (PNH) and atypical hemolytic–uremic syndrome (aHUS) exceeds $300,000 per patient. A better understanding of eculizumab pharmacokinetics and subsequent individual dose adjustment could reduce this cost. We measured the trough eculizumab concentration in 9 patients with maintenance therapy (aHUS, n = 7; PNH, n = 2) and determined: 1) the intra- and inter-individual variability; 2) the influence of weight on eculizumab pharmacokinetics; and 3) the rate of elimination of eculizumab following discontinuation. A one-compartment model was developed to describe the pharmacokinetics of eculizumab and predicted complement activity by body weight. Trough eculizumab concentrations were >50 µg/mL in 9/9, >100 µg/mL in 8/9, and >300 µg/mL in 5/9 of patients. Intra-individual variability was low but eculizumab concentrations, closely correlated with patient weight (R2 = 0.66, p = 0.034), varied broadly (55 ± 12 to 733 ± 164 µg/mL). Pharmacokinetic modeling showed that the elimination half-life varied greatly, with an increase from 7.8 d in a patient weighing 100 kg to 19.5 d in a 40 kg patient. We predicted that infusions of 1200 mg could be spaced every 4 or 6 weeks in patients weighing <90 and <70 kg, respectively. In this pilot study, the current recommended use of a fixed eculizumab dose for maintenance therapy is associated with excessively high trough concentrations in many patients. Further prospective larger studies are now required to support an individualized schedule adjusted for patient weight and based on the observed trough serum eculizumab concentration.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
customersupport@researchsolutions.com
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
This site is protected by reCAPTCHA and the Google Privacy Policy and Terms of Service apply.
Copyright © 2024 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.