Introduction: The use of a venipuncture simulator facilitates technique learning and improves skills, which reduces the risk of venipuncture complications in humans. Objective: To evaluate the efficacy of a non-human experimental model for Ultrasound guided superficial venipuncture. Methods: We randomized 39 nurses in two groups: A and B. The training had three steps: 1 - theoretical class, 2 - practical class, with the ultrasound device and 3 - ultrasound-guided puncture training in the non-human model. The group A participated in steps 1, 2 and 3 and group B in steps 1 and 2. After training, both groups were released for ultrasound guided venipuncture. Results: The success in puncture in group A (n = 20) was 90% and in group B (n = 19) it was 68.42%. In the sum of the identification and the puncture times, the average of group A was 61.5 seconds (95% CI, 33.58; 106.95) and in group B was 148.0 seconds (95% CI, 114.54; 208.44), which was statistically significant (p = 0.007, without overlapping the interval estimates). Conclusion: Nurses who received training with the nonhuman model had better identification and puncture times.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.