Three hundred twenty-four percutaneous inferior vena caval (IVC) filters of different designs were placed in 320 patients from April 1985 through June 1992. No acute mortality or substantial morbidity was attributed to filter placement. Radiologic or pathologic follow-up data were obtained in 227 (71%) patients (230 filters); clinical follow-up data only were obtained in 50 (16%) patients (50 filters). One hundred twenty (43%) patients died; post-filter-placement pulmonary emboli (PE) were related to the cause of death in eight. At IVC filter imaging studies, 26 of 137 (19%) filters demonstrated caval thrombus; 12 of 132 (9%) filters had delayed penetration through the IVC wall of greater than 3 mm; 13 of 230 (6%) filters migrated more than 1 cm; and five of 230 (2%) filters had fracture of a strut or leg. Deep venous thrombosis (DVT) at the insertion puncture site or in the lower extremity was noted in 26 of 117 (22%) cases of filter placement. Among patients without imaging studies, clinical suspicion of complications included PE in four patients, IVC thrombus in 14 patients, and lower-extremity DVT in 10 patients. Long-term clinical and radiologic follow-up of all IVC filters is indicated due to the relatively high prevalence of some complications.
A 20-MHz intravascular ultrasound (US) transducer inside a percutaneously inserted catheter was used to evaluate inferior vena caval (IVC) filters for thrombi in vitro and in vivo. Six different IVC filters were studied with intravascular US in a saline-filled model. Each filter had a characteristic, recognizable US pattern. Experimental thrombi as small as 0.5 cm3 were easily detected. Intravascular US was used clinically 25 times to evaluate the IVC in 23 patients with 24 IVC filters. Positive-contrast cavograms were available for comparison in all 25 cases. In 13 cases, no thrombi were identified in the filter or IVC with either intravascular US or cavography; in five of 12 cases with thrombi, intravascular US and cavography demonstrated the thrombi equally well. In six cases, intravascular US was superior to cavography in detection or delineation of thrombus in the IVC or filter. Intravascular US was considered superior to external duplex US in evaluation of caval thrombi in all 21 cases available for comparison. No complications from intravascular US were noted.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.