To investigate the applicability of piezosurgery for cervical ventral slot (CVS), comparing it with the conventional technique of using high-speed burs for bone wear. Methods: Thirty rabbits (Oryctolagus cuniculus) were divided into two treatment groups (T1 and T2) corresponding to CVS between C3-C4. In T1, the surgery was performed with piezoelectric apparatus, and in T2 with highspeed burs. The evaluated parameters were: duration of each stage of surgery, temperature variations during CVS, visibility of the surgical field, intra and postoperative complications, and anesthetic monitoring. At 14, 28, and 56 postoperative days, five animals from each treatment group were submitted for histopathological study of the surgical site. Results: Compared with T2, T1 had more precise bone cut, and better visibility of the operative field, although it required longer total surgical time (p = 0.02) and triggered a greater number of intraoperative complications (p < 0.01), microscopic lesions in the spinal cord (p < 0.05), and transient neurological deficits in the postoperatively (p < 0.05). Conclusion:It is necessary to perform surgical planning and have several tips of the piezoelectric instrument available for the safe use of the piezoelectric device in neurosurgery.
Background: Coxofemoral luxation is the most common traumatic luxation in dogs and the iliotrochanteric suture is one of the surgical treatment options. The orthopedic suture aimed at surgically restoring joint movement should be employed in an isometric manner in order to maintain adequate tension throughout the arc of motion. This study aimed to determine the isometric points for the iliotrochanteric suture in dogs during the joint extension and flexion movements. This evaluation was performed both in the intact hip joint and in the luxation model, establishing the best combination, among the determined points, for the reestablishment of normal joint movement.Materials, Methods & Results: Radiographic analyses of 12 canine cadaveric hips, both intact and in craniodorsal luxation model, were performed in a neutral position, flexion at 50°, and extension at 150°. In the trochanteric segment, two parallel lines were drawn, creating the central vertical axis and the secondary vertical axis. Three points were then determined on each axis, from proximal to distal, corresponding to 25, 50, and 75% of the height of the axis, and were labelled as T1, T2, and T3 and T4, T5, and T6, respectively. In the iliac segment, a line perpendicular to the longitudinal axis of the ilium was drawn, and 25, 50, and 75% of this height corresponded to points I1, I2, and I3, respectively. The lengths between the points were measured, with the objective of evaluating which combination of points presented less variation in the joint positions. The central location of the iliac and trochanteric segments, determined respectively by I2 and T2, provided smaller variations during the maximal movements of hip flexion and extension.Discussion: The surgical techniques of iliotrochanteric suture target to maintain the internal rotation of the femoral head inside the acetabulum and abduction of the femur until the soft tissues have healed. The described techniques for the iliotrochanteric suture present a great anatomical variety in the arrangement of the anchor points of the suture. It is known that if during motion, the attachment sites move closer to one another, the suture will become lax and, if the attachment sites move away from one another, the suture will tighten. Therefore, the implantation in isometric sites assists in reducing the variation of the distance between the points of origin and insertion of the suture during joint movement, keeping the suture tension constant and allowing the functional recovery of the joint. This study demonstrates that there are some locations for the origin and insertion of an iliotrochanteric suture that are associated with less length change than others. I2-T2 combination is the point closest to isometry for the iliotrochanteric suture during hip extension and flexion, so that, T2 is the most central point of the greater trochanter, corresponding to 50% of the height of its central vertical axis, as well as I2, which corresponds to the most central point of the ilium, representing 50% of the height of the most caudal portion of its body. The isometric point found by us details the exact location of perforation in all aspects (height and length), both in the ilium and the trochanter. In addition, it is a personalized point created for each patient from its radiographic examination and taking into consideration its anatomical variations, so that there is no damage to the suture during hip extension and flexion movements.
A six-month-old male Brazilian Terrier with persistent cough and dyspnea was diagnosed with intrathoracic tracheal collapse and pneumonia after chest radiographics. The medical treatment was performed, and an extraluminal nitinol prosthesis was placed through thoracic access. The dog did not presented recurrence of dyspnea or pneumonia for four years after the surgical procedure. Placement of the extraluminal prosthesis with the thoracic approach effectively stabilized intrathoracic tracheal collapse without causing any structural damage in the thoracic region. Therefore, this is the first report of a successful use of this prosthesis with an intercostal approach in dogs for intrathoracic trachea collapse.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
customersupport@researchsolutions.com
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
This site is protected by reCAPTCHA and the Google Privacy Policy and Terms of Service apply.
Copyright © 2024 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.