Background and aimsAlthough dental implants are widely and successfully used, failure rates because of bacterial colonization are still high. Adequate fabrication and sterilization techniques as well as proper management of infectious complications represent a constant field of interest and research. In this study, we focused our attention on implants with controlled porosity produced by Selective Laser Melting (SLM). The difficulty to sterilize porous implantable devices is well known and finding an adequate sterilization protocol represents a challenge worldwide. Before testing the biological and mechanical properties of porous implants, a preliminary study in order to determine a correct sterilization protocol must be conducted.Our aim was to establish a valid sterilization protocol for porous titanium alloy dental implants, as such protocols are not officially available yet.MethodsTwenty dental implants were fabricated from a titanium alloy by SLM. Ten of them were made using a 150W laser beam (porosity of 1% - group A) and the rest using a 75W laser beam (porosity of 23% - Group B), all of them with a non-defined internal structure. The implants were initially sterilized (5 from group A and 5 from group B, using dry heat - 180°C for 2 hours; the rest using steam sterilization - 121 °C for15 min) and then spent 18 hours in culture media with developing bacteria (Bacillus cereus (ATCC 11778), Staphylococcus aureus (ATCC 49444), Enterococcus faecalis (ATCC 29212), Listeria monocytogenes (ATCC 19114), three Gram negative bacteria: Escherichia coli (ATCC 25922), Salmonella typhimurium (ATCC 14028) and Pseudomonas aeruginosa (ATCC 27853). The first ten implants (5 from group A and 5 from group B) were then sterilized with dry heat and the others with steam. After sterilization, they were all placed in sterile culture media in order to observe if any bacterial growth were present.ResultsThe culture media was observed 18 hours after the sterilized implants were placed inside. No bacterial growth was observed.ConclusionsOur tests reached their aims of defining a protocol to sterilize porous implants. Future tests regarding biological and mechanical aspects of these implants may now follow.
Background and Objectives: Dental occlusion and gingival recession have been studied over the past years especially because of the increasing incidence of occlusal interferences in young patients. The purpose of this pilot study is to investigate any association between occlusal dysfunctions and gingival recessions. Data on gingival phenotype and previous orthodontic treatment were also collected to assess any correlation with the presence of gingival recession. Materials and Methods: Forty systemically healthy subjects, without signs of periodontitis and with gingival recessions, were included in the study. The following parameters were determined: location and extent of the gingival recession, gingival phenotype and functional occlusion by means of observing and registering the occlusal contacts in maximum intercuspation position, protrusive and lateral guidance. Results: Premolars were mostly affected in cases of working-side interferences during lateral guidance (71.19% of the affected teeth during left and 75% during right mandibular movements). The chi-squared exact test applied for the analysis of contingency tables revealed statistically significant associations between excursive interferences during lateral guidance and anterior guidance and the presence of gingival recession on the involved group of teeth. Conclusions: The results suggest that most gingival recessions might be associated with working-side interferences, the highest number of gingival recessions being associated with active interferences during lateral guidance.
Experimental animal models for studying the mechanisms of periodontitis and its links are a better alternative to in vitro studies. The aim of this study is to compare two ligature induced periodontitis models and validate the best one for further use in research. An experimental study was performed on male Wistar rats that were divided into three groups: Test 1 (n = 10), incisor ligated, Test 2 (n = 10), molar ligated, and Control (n = 10). The animals were clinically evaluated at the beginning and at the end of the experiment by recording body weight, gingival bleeding index, tooth mobility score, changes in color, and consistency of gingival tissue. Two blood samples were obtained for each animal at baseline and at the end of the experiment. The hematological parameters Interleukin-1 alpha (IL-1 α), high sensitive C Reactive Protein (hsCRP), and Tumor Necrosis Factor-alpha (TNF-α) were measured. Seven days after the induction of periodontitis, the animals were sacrificed, and samples were prepared for histological evaluation. The results of this research demonstrated that the association between clinical, histological, and biochemical parameters initiate a periodontal pathology in the molar induced model in rats while the incisor experimental model initiates only a moderate and incomplete periodontal inflammation, mainly due to mechanical irritation.
The objective of the present study was to evaluate the 5-year outcome of dental implant therapy and assess the survival, success, and biological and technical complications. A periodontal and prosthetic-oriented evaluation was conducted on the variables that can influence the long-term predictability of implant therapy. A total of 615 patients and 1427 dental implants from a private clinic (MedArtis Dent, Cluj-Napoca, Romania) were enrolled in the study. The study was a longitudinal cohort with data collected retrospectively from physical/digital dental records in combination with a cross-sectional clinical/radiological examination. Results showed that periodontal diagnosis at baseline had a significant impact on the marginal bone loss prediction. Data showed that the cylindrical implant with an internal 45° medium taper connection experienced a higher rate of bone resorption compared to the tapered implant with the 5° internal connection. Screw-retained restorations and overdentures showed a statistical decrease in the marginal bone level height when compared to the cemented restorations. Data from our study suggest that not only is there a powerful association between recall visits and the rate of complications in dental implant treatment, but a lack of professional maintenance predicts a higher bone level loss during the 5-year interval.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
customersupport@researchsolutions.com
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
This site is protected by reCAPTCHA and the Google Privacy Policy and Terms of Service apply.
Copyright © 2024 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.