Air samples were collected in 12 randomly selected commercial nail salons in Salt Lake County, Utah. Measurements of salon physical/chemical parameters (room volume, CO2 levels) were obtained. Volatile organic compound (VOC) concentrations were collected using summa air canisters and sorbent media tubes for an 8-h period. Multivariate analyses were used to identify relationships between salon physical/chemical characteristics and the VOCs found in the air samples. The ACGIH(®) additive mixing formula was also applied to determine if there were potential overexposures to the combined airborne concentrations of chemicals monitored. Methyl methacrylate was detected in 58% of the establishments despite having been banned for use in nail products by the state of Utah. Formaldehyde was found above the NIOSH REL(®) (0.016 ppm) in 58% of the establishments. Given the assortment of VOCs to which nail salon workers are potentially exposed, a combination of engineering as well as personal protective equipment is recommended.
The state-of-the-art for personal sampling for inhalable aerosol hazards is constrained by issues of sampler cost and complexity; these issues have limited the adoption and use of some samplers by practicing hygienists. Thus, despite the known health effects of inhalable aerosol hazards, personal exposures are routinely assessed for only a small fraction of the at-risk workforce. To address the limitations of current technologies for inhalable aerosol sampling, a disposable inhalable aerosol sampler was developed and evaluated in the laboratory. The new sampler is designed to be less expensive and simpler to use than existing technologies. The sampler incorporates a lightweight internal capsule fused to the sampling filter. This capsule-filter assembly allows for the inclusion of particles deposited on the internal walls and inlet, thus minimizing the need to wash or wipe the interior sampling cassette when conducting gravimetric analyses. Sampling efficiency and wall losses were tested in a low-velocity wind tunnel with particles ranging from 9.5 to 89.5 μm. The results were compared to the proposed low-velocity inhalability criterion as well as published data on the IOM sampler. Filter weight stability and time-to-equilibrium were evaluated as these factors affect the practicality of a design. Preliminary testing of the new sampler showed good agreement with both the IOM and the proposed low-velocity inhalability curve. The capsule and filter assemblies reached equilibrium within 25h of manufacturing when conditioned at elevated temperatures. After reaching equilibrium, the capsule-filter assemblies were stable within 0.01mg.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.