Purpose To examine the performance of state-of-the-art wavefront-guided scleral contact lenses (wfgSCLs) on a sample of keratoconic eyes, with emphasis on performance quantified with visual quality metrics; and to provide a detailed discussion of the process used to design, manufacture and evaluate wfgSCLs. Methods Fourteen eyes of 7 subjects with keratoconus were enrolled and a wfgSCL was designed for each eye. High-contrast visual acuity and visual quality metrics were used to assess the on-eye performance of the lenses. Results The wfgSCL provided statistically lower levels of both lower-order RMS (p < 0.001) and higher-order RMS (p < 0.02) than an intermediate spherical equivalent scleral contact lens. The wfgSCL provided lower levels of lower-order RMS than a normal group of well-corrected observers (p < < 0.001). However, the wfgSCL does not provide less higher-order RMS than the normal group (p = 0.41). Of the 14 eyes studied, 10 successfully reached the exit criteria, achieving residual higher-order root mean square wavefront error (HORMS) less than or within 1 SD of the levels experienced by normal, age-matched subjects. In addition, measures of visual image quality (logVSX, logNS and logLIB) for the 10 eyes were well distributed within the range of values seen in normal eyes. However, visual performance as measured by high contrast acuity did not reach normal, age-matched levels, which is in agreement with prior results associated with the acute application of wavefront correction to KC eyes. Conclusions Wavefront-guided scleral contact lenses are capable of optically compensating for the deleterious effects of higher-order aberration concomitant with the disease, and can provide visual image quality equivalent to that seen in normal eyes. Longer duration studies are needed to assess whether the visual system of the highly aberrated eye wearing a wfgSCL is capable of producing visual performance levels typical of the normal population.
We report measurements of the absolute threshold of cone vision, which has been previously underestimated due to sub-optimal conditions or overly strict subjective response criteria. We avoided these limitations by using optimized stimuli and experimental conditions while having subjects respond within a rating scale framework. Small (1′ fwhm), brief (34 msec), monochromatic (550 nm) stimuli were foveally presented at multiple intensities in dark-adapted retina for 5 subjects. For comparison, 4 subjects underwent similar testing with rod-optimized stimuli. Cone absolute threshold, that is, the minimum light energy for which subjects were just able to detect a visual stimulus with any response criterion, was 203 ± 38 photons at the cornea, ∼0.47 log units lower than previously reported. Two-alternative forced-choice measurements in a subset of subjects yielded consistent results. Cone thresholds were less responsive to criterion changes than rod thresholds, suggesting a limit to the stimulus information recoverable from the cone mosaic in addition to the limit imposed by Poisson noise. Results were consistent with expectations for detection in the face of stimulus uncertainty. We discuss implications of these findings for modeling the first stages of human cone vision and interpreting psychophysical data acquired with adaptive optics at the spatial scale of the receptor mosaic.
Purpose To: 1) quantify on-eye rotational and translational stability of three scleral contact lens stabilization methods and 2) model the variation in visual acuity when these movements occur in a wavefront-guided correction for highly aberrated eyes. Methods Three lens stabilization methods were integrated into the posterior periphery of a scleral contact lens designed at the Visual Optics Institute. For comparison, a lens with no stabilization method (rotationally symmetric posterior periphery) was designed. The lenses were manufactured and lens movements were quantified on eight eyes as the average standard deviation of the observed translations and rotations over 60 minutes of wear. In addition, the predicted changes in acuity for 5 eyes with keratoconus wearing a simulated wavefront-guided correction (full correction through the fifth order) were modeled using the measured movements. Results For each lens design, no significant differences in the translation and rotation were found between left and right eyes, and lenses behaved similarly on all subjects. All three designs with peripheral stability modifications exhibited no statistically significant differences in translation and rotation distributions of lens movement and were statistically more stable than the spherical lens in rotation. When the measured movements were used to simulate variation in visual performance, the three lenses with integrated stability methods showed a predicted average loss in acuity from the perfectly aligned condition of approximately 0.06 logMAR (3 letters), compared to the loss of over 0.14 logMAR (7 letters) for the lens with the spherical periphery. Conclusions All three stabilization methods provided superior stability, as compared to the spherical lens design. Simulations of the optical and visual performance suggest that all three stabilization designs can provide desirable results when utilized in the delivery of a wavefront-guided correction for a highly aberrated eye.
Current vision science adaptive optics systems use near infrared wavefront sensor ‘beacons’ that appear as red spots in the visual field. Colored fixation targets are known to influence the perceived color of macroscopic visual stimuli(Jameson, D. and Hurvich, L. M., 1967. Fixation-light bias: an unwanted by-product of fixation control. Vis. Res. 7, 805 – 809.), suggesting that the wavefront sensor beacon may also influence perceived color for stimuli displayed with adaptive optics. Despite its importance for proper interpretation of adaptive optics experiments on the fine scale interaction of the retinal mosaic and spatial and color vision, this potential bias has not yet been quantified or addressed. Here we measure the impact of the wavefront sensor beacon on color appearance for dim, monochromatic point sources in 5 subjects. The presence of the beacon altered color reports both when used as a fixation target as well as when displaced in the visual field with a chromatically neutral fixation target. This influence must be taken into account when interpreting previous experiments and new methods of adaptive correction should be used in future experiments using adaptive optics to study color.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
customersupport@researchsolutions.com
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
This site is protected by reCAPTCHA and the Google Privacy Policy and Terms of Service apply.
Copyright © 2024 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.