ObjectiveTo develop ultrasound (US) definitions and a US novel scoring system for major salivary gland (SG) lesions in patients with primary Sjögren’s syndrome (pSS) and to test their intrareader and inter-reader reliability using US video clips.MethodsTwenty-five rheumatologists were subjected to a three-round, web-based Delphi process in order to agree on (1) definitions and scanning procedure of salivary gland ultrasonography (SGUS): parotid, submandibular and sublingual glands (PG, SMG and SLG); (2) definitions for the elementary SGUS lesions in patients with Sjögren’s syndrome; (3) scoring system for grading changes. The experts rated the statements on a 1–5 Likert scale. In the second step, SGUS video clips of patients with pSS and non-pSS sicca cases were collected containing various spectrums of disease severity followed by an intrareader and inter-reader reliability exercise. Each video clip was evaluated according to the agreed definitions.ResultsConsensual definitions were developed after three Delphi rounds. Among the three selected SGs, US assessment of PGs and SMGs was agreed on. Agreement was reached to score only greyscale lesions and to focus on anechoic/hypoechoic foci in a semiquantitative matter or, if not possible on a qualitatively (present/absent) evaluation of fatty or fibrous lesions. Intrareader reliability for detecting and scoring these lesions was excellent (Cohen’s kappa 0.81) and inter-reader reliability was good (Light’s kappa 0.66).ConclusionNew definitions for developing a novel semiquantitative US score in patients with pSS were developed and tested on video clips. Inter-reader and intrareader reliabilities were good and excellent, respectively.
Based on the results of our exercise, the OMERACT US definitions for the identification of CPPD demonstrated to be reliable when applied to the TFC and AC. Other sites reached good kappa values in the web-based exercise but failed to achieve good reproducibility at the patient-based exercise, meaning the scanning method must be further refined.
ObjectiveTo evaluate the discriminatory ability of ultrasound in calcium pyrophosphate deposition disease (CPPD), using microscopic analysis of menisci and knee hyaline cartilage (HC) as reference standard.MethodsConsecutive patients scheduled for knee replacement surgery, due to osteoarthritis (OA), were enrolled. Each patient underwent ultrasound examination of the menisci and HC of the knee, scoring each site for presence/absence of CPPD. Ultrasound signs of inflammation (effusion, synovial proliferation and power Doppler) were assessed semiquantitatively (0–3). The menisci and condyles, retrieved during surgery, were examined microscopically by optical light microscopy and by compensated polarised microscopy. CPPs were scored as present/absent in six different samples from the surface and from the internal part of menisci and cartilage. Ultrasound and microscopic analysis were performed by different operators, blinded to each other’s findings.Results11 researchers from seven countries participated in the study. Of 101 enrolled patients, 68 were included in the analysis. In 38 patients, the surgical specimens were insufficient. The overall diagnostic accuracy of ultrasound for CPPD was of 75%—sensitivity of 91% (range 71%–87% in single sites) and specificity of 59% (range 68%–92%). The best sensitivity and specificity were obtained by assessing in combination by ultrasound the medial meniscus and the medial condyle HC (88% and 76%, respectively). No differences were found between patients with and without CPPD regarding ultrasound signs of inflammation.ConclusionUltrasound demonstrated to be an accurate tool for discriminating CPPD. No differences were found between patents with OA alone and CPPD plus OA regarding inflammation.
We compared the efficacy and safety of intra-articular hylan G-F 20 with methylprednisolone acetate (MPA) for treating symptomatic Kellgren-Lawrence grade (KLG) 2 or 3 hip osteoarthritis in a prospective, randomized, multicenter, double-blind trial (N = 313). Two injections of hylan G-F 20 were administered 2 weeks apart (n = 150), or 1 injection of 40 mg MPA and 1 sham injection 2 weeks later (n = 155). The Western Ontario and McMaster Universities Arthritis Index (WOMAC) (total and subscale), clinician observations, and patient global assessments were collected at baseline and at weeks 4, 8, 12, 16, 20, and 26 (intent-to-treat population was analyzed; n = 305). Responder rates were assessed by WOMAC domain A, and criteria were established by the Outcome Measures in Rheumatology Clinical Trials-Osteoarthritis Research Society International (OMERACT-OARSI). At week 26, WOMAC A improved by 16.6 mm for hylan G-F 20 versus 13.6 mm for MPA. Response rates were higher with hylan G-F 20 versus MPA in patients with more advanced disease (KLG 3) and were similar between hylan G-F 20 and MPA in patients with less advanced disease (KLG 2). Adverse events were similar between groups and between patients with KLG 2 or 3. Hylan G-F 20 provided clinically meaningful improvements in pain and function, comparable with those of MPA, with good safety and tolerability. Thus, we conclude it is an appropriate option for treating hip osteoarthritis.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.