Phononic crystals are resonant structures with great potential to be implemented in applications as liquid sensors. The use of the symmetry reduction technique allows introducing relevant transmission features inside bandgaps by creating defect modes in a periodic regular structure. These features can be used as measures to quantify changes in the speed of sound of liquid samples that could be related to the concentration of analytes or the presence of pathogens among other interesting applications. In order to be able to implement this new technology in more challenging applications, such as biomedical applications, it is necessary to have a very precise and accurate measurement. Changes in temperature greatly affect the speed of sound of the liquid samples, causing errors in the measurements. This article presents a phononic crystal sensor that, by introducing additional defect modes, can carry out differential measurements as a temperature compensation mechanism. Theoretical studies using the transmission line model and analytes at various temperatures show that the proposed temperature compensation mechanism enhances the performance of the sensor in a significant way. This temperature compensation strategy could also be implemented in crystals with different topologies.
Phononic crystals are periodic composite structures with specific resonant features that are gaining strength in the field as liquid sensors. The introduction of a structural defect in an otherwise periodic regular arrangement can generate a resonant mode, also called defect mode, inside the characteristic band gaps of phononic crystals. The morphology, as well as the frequency in which these defect modes appear, can give useful information on the composition and properties of an analyte. Currently, only gain, and frequency measurements are performed using phononic crystal sensors. Other measurements like the transient response have been implemented in resonant sensors such as quartz microbalances showing great results and proving to be a great complimentary measure to the gain and frequency measurements. In the present paper, a study of the feasibility of using the transient response as a measure to acquire additional information about the analyte is presented. Theoretical studies using the transmission line model were realized to show the impact of variations in the concentration of an analyte, in this case, lithium carbonate solutions, in the transient time of the system. Experimental realizations were also performed showing that the proposed measurement scheme presents significant changes in the resulting data, indicating the potential use of this measure in phononic crystal sensors. This proposed measure could be implemented as a stand-alone measure or as a compliment to current sensing modalities.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
customersupport@researchsolutions.com
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
This site is protected by reCAPTCHA and the Google Privacy Policy and Terms of Service apply.
Copyright © 2024 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.