The use of digital radiography is becoming more prevalent in orthopedics. This transition impacts the ability to preoperatively plan for implants in total hip arthroplasty (THA) and total knee arthroplasty (TKA). This article reports on the clinical success of digital templating using the Advanced Case Plan (Stryker Imaging, Flower Mound, Texas) system in primary THA and TKA. Digital radiographs of 269 consecutive patients undergoing primary THA (93 cases) or TKA (176 cases) were templated using the Advanced Case Plan digital software package. A 25.4-mm metallic sphere was used as a calibrating marker. Anteroposterior hip and lateral knee radiographs were digitally templated preoperatively and compared to the actual size of the implants at the time of surgery. The accuracy of calibrating images using the metallic sphere was validated by measuring the diameter of femoral heads on 25 postoperative hip radiographs. Digital templating was accurate in predicting the correct implant size in 58.5% of THAs and 66% of TKAs. In 93% of THAs and 98.5% of TKAs, preoperative templating was within 1 size of the final implant. There were no cases in which the predicted implant size varied from the final components by>2 sizes. Calibrating the image using the metallic sphere marker was found to be highly accurate, predicting the correct femoral head size within 1.5 mm in all 25 cases (7 hemiarthroplasties and 18 THAs). Digital templating is an effective means for predicting the size of THA and TKA components, thus remaining a viable option as we transition into the modern era of digital radiography. Future studies will evaluate interobserver reliability and the impact of level of training on templating accuracy.
Early failures of metal-on-metal total hip arthroplasty (THA) occur due to aseptic loosening, metal hypersensitivity reactions, pseudotumor formation, and component seizing. The purpose of this study was to investigate the timing, common modes of failure, clinical outcomes, and incidence of metal-on-metal THA revisions. A review was performed of 80 patients who underwent revision of a failed metal-on-metal THA for any reason. The most common reason for metal-on-metal failure was aseptic acetabular loosening, with a rate of 56.25% (45/80 patients). Early failure of metal-on-metal THAs was noted, with 78% of these revisions being performed within 2 years of the index operation and 92.5% within 3 years. Furthermore, 13% of patients experienced significant localized soft tissue reactions. Mean preoperative Harris Hip Score was 42.35 ± 14.24 and mean postoperative Harris Hip Score was 66.5 ± 23.2 (range, 9.55-95.4), with an average follow-up of 438 ± 492 days (range, 40-2141), or 1.2 years.It is imperative that clinicians be cognizant of the fact that the proposed advantages of metal-on-metal THA are not without potential detrimental sequelae. This article proposes an algorithm to aid in diagnosing the etiology of a painful metal-on-metal THA, as well as 2 classification schemes regarding metal-on-metal THA complications to help direct treatment.
Hip fracture is one of the most common injuries among the elderly and, because the population is aging, it is expected to remain a major clinical challenge and public health problem for the foreseeable future. The clinical importance of early mobilization and prompt participation in physical therapy after hip fracture surgery is now widely recognized. Because postoperative pain can impair mobility and delay physical therapy, much attention is now being paid to finding more effective ways of controlling pain after hip fracture. Oversedation with opioid drugs inhibits communication between the patient and the health care team, can delay ambulation and rehabilitation therapy, and may increase the probability of the patient requiring a skilled nursing facility, which adds further cost to the overall health care system. Multiple pain pathways contribute to the perception of postoperative pain, and although opioids are highly effective in blocking nociceptive pain through inhibition of the mu receptors, they do not block other pain pathways. Multimodal analgesia involves the use of several anesthetic and analgesic modalities that are strategically combined to block pain perception at different sites in the peripheral and central nervous systems. This balanced, multifaceted approach provides more effective control of postoperative pain than opioid drugs alone, allows lower doses of opioids to be used as part of the multimodal regimen (thereby reducing the risk of opioid-related adverse events and complications), and may facilitate more rapid recovery and improve certain outcome measures related to recovery time. One prospective randomized study evaluating the clinical value of multimodal pain management in elderly patients undergoing bipolar hip hemiarthroplasty found that a multimodal regimen, including preemptive pain medication and intraoperative periarticular injections, reduced pain on postoperative days 1 and 4, and reduced overall opioid use. This article describes an effective multimodal pain management regimen for hip fracture patients.
The development of porous metals and coatings for orthopaedic applications has revolutionized the medical field. The ability to bond metallic implants to bone has spawned the advancements in total joint arthroplasty we have experienced over the last 4 decades. Early success was obtained as factors (pore size, coefficient of friction, modulus of elasticity) necessary for osseointegration were just being discovered. Despite good results, initial implant designs were fabricated utilizing traditional coatings (i.e. sintered beads, fiber metal, plasma spray), which have several inherent limitations, including relatively high moduli of elasticity, low coefficient of frictions and intermediate porosity. In order to improve upon these limitations and capitalize on modern techniques for implant fabrication several new porous metals have been recently introduced in orthopaedics. Tritanium (Stryker, Mahwah, NJ), Regenerex (Biomet, Warsaw, IN), StikTite (Smith and Nephew, Memphis, TN), Gription (Depuy, Warsaw, IN), Biofoam (Wright Medical, Arlington, TX), and Trabecular Metal (Zimmer, Warsaw, IN) are currently available for orthopaedic surgery applications. These materials have moved us into the era metallic foams that possess a characteristic appearance similar to cancellous bone. The open-cell internal structure of these metals afford several interesting biomaterial properties, including; high volumetric porosity (60-80 %), low modulus of elasticity and high surface frictional characteristics. The following chapter reviews the mode of fabrication, properties and applications in orthopaedic surgery for this new class of highly porous metals.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
customersupport@researchsolutions.com
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
This site is protected by reCAPTCHA and the Google Privacy Policy and Terms of Service apply.
Copyright © 2025 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.