<b><i>Background:</i></b> We tested a new, investigational robotic-assisted bronchoscope system with a remotely controlled catheter to access small peripheral bronchi with real-time driving under live visualization and distal tip articulation of the catheter. The unique catheter remains stationary once located at the biopsy position. <b><i>Objectives:</i></b> The primary objectives of this study were to evaluate the safety and feasibility of a new shape-sensing robotic bronchoscope system to bronchoscopically approach and facilitate the sampling of small peripheral pulmonary nodules of 1–3 cm. Secondary objectives included evaluating procedural characteristics and early performance trends associated with the use of the new robotic bronchoscope system. <b><i>Methods:</i></b> Subjects were enrolled according to study eligibility criteria at a single center. Navigation pathways were semi-automatically created using pre-procedure CT scans. Simultaneous (real-time) viewing of actual and virtual bronchi was used real time during navigation to the displayed target. An endobronchial ultrasound mini-probe was used to confirm lesion location. Flexible 19- to 23-G needles specifically designed to accommodate tight bend radii in transbronchial needle aspiration were used along with conventional biopsy tools. Enrolled subjects completed follow-up visits up to 6 months after the procedure. <b><i>Results:</i></b> The study included 29 subjects with a mean lesion size of 12.2 ± 4.2, 12.3 ± 3.3, and 11.7 ± 4.1 mm in the axial, coronal, and sagittal planes, respectively. The CT bronchus sign was absent in 41.4% of cases. In 96.6% of cases, the target was reached, and samples were obtained. No device-related adverse events and no instances of pneumothorax or excessive bleeding were observed during the procedure. Early performance trends demonstrated an overall diagnostic yield of 79.3% and a diagnostic yield for malignancy of 88%. <b><i>Conclusion:</i></b> This new robotic-assisted bronchoscope system safely navigated to very small peripheral airways under continuous visualization, and through maintenance of a static position, it provides a unique sampling capability for the biopsy of small solitary pulmonary nodules.
Our previous phase II study of cisplatin and gemcitabine in malignant mesothelioma showed a 47.6% (95% CI 26.2 -69.0%) response rate with symptom improvement in responding patients. Here we confirm these findings in a multicentre setting, and assess the effect of this treatment on quality of life and pulmonary function. Fifty-three patients with pleural malignant mesothelioma received cisplatin 100 mg m 72 i.v. day 1 and gemcitabine 1000 mg m 72 i.v. days 1, 8, and 15 of a 28 day cycle for a maximum of six cycles. Quality of life and pulmonary function were assessed at each cycle. The best response achieved in 52 assessable patients was: partial response, 17 (33%, 95% CI 20 -46%); stable disease, 31 (60%); and progressive disease, four (8%). The median time to disease progression was 6.4 months, median survival from start of treatment 11.2 months, and median survival from diagnosis 17.3 months. Vital capacity and global quality of life remained stable in all patients and improved significantly in responding patients. Major toxicities were haematological, limiting the mean relative dose intensity of gemcitabine to 75%. This schedule of cisplatin and gemcitabine is active in malignant mesothelioma in a multicentre setting. Investigation of alternative scheduling is needed to decrease haematological toxicity and increase the relative dose intensity of gemcitabine whilst maintaining response rate and quality of life.
Rapid on-site evaluation (ROSE) of endobronchial ultrasound-guided transbronchial needle aspirates (EBUS-TBNA) has not been compared to final detailed cytological analysis in patients with suspected sarcoidosis.To assess the diagnostic accuracy of EBUS-TBNA with ROSE in patients with suspected sarcoidosis, a prospective two-centre study performed EBUS-TBNA with ROSE of cellular material followed by transbronchial lung biopsy (TBLB) and endobronchial biopsy (EBB). The diagnostic accuracy of EBUS-TBNA with ROSE was compared to the final cytological assessment and to TBLB and EBB.Analysis confirmed 49 out of 60 cases of sarcoidosis. ROSE sensitivity was 87.8% (specificity 91%, positive predictive value 97.7%). ROSE slide interpretation in combination with the final fixed slide and cell block preparations had a sensitivity of 91.8% (specificity 100%, positive predictive value 100%). 67% of patients were confirmed as having sarcoidosis on TBLB and 29% on EBB. Interobserver agreement between cytotechnologists and pathologists was very good (k50.91, 95% CI 0.80-1.0 and k50.91, 95% CI 0.79-1.0, respectively).EBUS-TBNA with ROSE has high diagnostic accuracy and interobserver agreement and informs the bronchoscopist in theatre whether additional diagnostic procedures need to be undertaken. EBUS-TBNA with ROSE should therefore be considered as the first-line investigation of sarcoidosis. @ERSpublications Rapid on-site evaluation of EBUS-TBNA should be first-line investigation in sarcoidosis
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
customersupport@researchsolutions.com
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
This site is protected by reCAPTCHA and the Google Privacy Policy and Terms of Service apply.
Copyright © 2024 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.