Hybridization of nanoscale metals and carbon nanotubes into composite nanomaterials has produced some of the best-performing sensors to date. The challenge remains to develop scalable nanofabrication methods that are amenable to the development of sensors with broad sensing ranges. A scalable nanostructured biosensor based on multilayered graphene petal nanosheets (MGPNs), Pt nanoparticles, and a biorecognition element (glucose oxidase) is presented. The combination of zero-dimensional nanoparticles on a two-dimensional support that is arrayed in the third dimension creates a sensor platform with exceptional characteristics. The versatility of the biosensor platform is demonstrated by altering biosensor performance (i.e., sensitivity, detection limit, and linear sensing range) through changing the size, density, and morphology of electrodeposited Pt nanoparticles on the MGPNs. This work enables a robust sensor design that demonstrates exceptional performance with enhanced glucose sensitivity (0.3 µ M detection limit, 0.01-50 m M linear sensing range), a long stable shelf-life ( > 1 month), and a high selectivity over electroactive, interfering species commonly found in human serum samples.
We report a novel optical biosensor platform using near-infrared (NIR) fluorescent single-walled carbon nanotubes (SWNTs) functionalized with target-recognizing aptamer DNA for noninvasively detecting cell signaling molecules in real-time. Photoluminescence (PL) emission of aptamer-coated SWNTs is modulated upon selectively binding to target molecules, which is exploited to detect insulin using an insulin-binding aptamer (IBA) as a molecular recognition element. We find that nanotube PL quenches upon insulin recognition via a photoinduced charge transfer mechanism with a quenching rate of kq = 5.85×1014 M−1s−1 and a diffusion-reaction rate of kr = 0.129 s−1. Circular dichroism spectra reveal for the first time that IBA strands retain a four-stranded, parallel guanine quadruplex conformation on the nanotubes, ensuring target selectivity. We demonstrate that these IBA-functionalized SWNT sensors incorporated in a collagen extracellular matrix (ECM) can be regenerated by removing bound analytes through enzymatic proteolysis. As proof-of-concept, we show that the SWNT sensors embedded in the ECM promptly detect insulin secreted by cultured pancreatic INS-1 cells stimulated by glucose influx and report a gradient contour of insulin secretion profile. This novel design enables new types of label-free assays and non-invasive, in-situ, real-time detection schemes for cell signaling molecules.
Decreased interstitial flow (IF) in secondary lymphedema is coincident with poor physiological lymphatic regeneration. However, both the existence and direction of causality between IF and lymphangiogenesis remain unclear. This is primarily because the role of IF and its importance relative to the action of the prolymphangiogenic growth factor vascular endothelial growth factor (VEGF)-C (which signals primarily through its receptor VEGFR-3) are poorly understood. To clarify this, we explored the cooperative roles of VEGFR-3 and IF in a mouse model of lymphangiogenesis in regenerating skin. Specifically, a region of lymphangiogenesis was created by substituting a portion of mouse tail skin with a collagen gel within which lymphatic capillaries completely regenerate over a period of 60 days. The relative importance of IF and VEGF-C signaling were evaluated by either inhibiting VEGFR-3 signaling with antagonistic antibodies or by reducing IF. In some cases, VEGF-C signaling was then increased with exogenous protein. To clarify the role of IF, the distribution of endogenous matrix metalloproteinases (MMPs) and VEGF-C within the regenerating region was determined. It was found that inhibition of either VEGFR-3 or IF suppressed endogenous lymphangiogenesis. Reduction of IF was found to decrease lymphatic migration and transport of endogenous MMP and VEGF-C through the regenerating region. Therapeutic VEGF-C administration restored lymphangiogenesis following inhibition of VEGFR-3 but did not increase lymphangiogenesis following inhibition of IF. These results identify IF as an important regulator of the pro-lymphangiogenic action of VEGF-C.
Glucose is the central molecule in many biochemical pathways, and numerous approaches have been developed for fabricating micro biosensors designed to measure glucose concentration in/near cells and/or tissues. An inherent problem for microsensors used in physiological studies is a low signal-to-noise ratio, which is further complicated by concentration drift due to the metabolic activity of cells. A microsensor technique designed to filter extraneous electrical noise and provide direct quantification of active membrane transport is known as self-referencing. Self-referencing involves oscillation of a single microsensor via computer-controlled stepper motors within a stable gradient formed near cells/tissues (i.e., within the concentration boundary layer). The non-invasive technique provides direct measurement of trans-membrane (or trans-tissue) analyte flux. A glucose micro biosensor was fabricated using deposition of nanomaterials (platinum black, multiwalled carbon nanotubes, Nafion) and glucose oxidase on a platinum/iridium microelectrode. The highly sensitive/selective biosensor was used in the self-referencing modality for cell/tissue physiological transport studies. Detailed analysis of signal drift/noise filtering via phase sensitive detection (including a post-measurement analytical technique) are provided. Using this highly sensitive technique, physiological glucose uptake is demonstrated in a wide range of metabolic and pharmacological studies. Use of this technique is demonstrated for cancer cell physiology, bioenergetics, diabetes, and microbial biofilm physiology. This robust and versatile biosensor technique will provide much insight into biological transport in biomedical, environmental, and agricultural research applications.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
customersupport@researchsolutions.com
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
This site is protected by reCAPTCHA and the Google Privacy Policy and Terms of Service apply.
Copyright © 2024 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.