Background Enhanced methods of drug monitoring are required to support the individualisation of antibiotic dosing. We report the first-in-human evaluation of real-time phenoxymethylpenicillin monitoring using a minimally invasive microneedle-based β-lactam biosensor in healthy volunteers.
Antimicrobial resistance poses a global threat to patient health. Improving the use and effectiveness of antimicrobials is critical in addressing this issue. This includes optimising the dose of antibiotic delivered to each individual. New sensing approaches that track antimicrobial concentration for each patient in real time could allow individualised drug dosing. This work presents a potentiometric microneedlebased biosensor to detect levels of β-lactam antibiotics in vivo in a healthy human volunteer. The biosensor is coated with a pH-sensitive iridium oxide layer, which detects changes in local pH as a result of β-lactam hydrolysis by β-lactamase immobilised on the electrode surface. Development and optimisation of the biosensor coatings are presented, giving a limit of detection of 6.8 µM in 10 mM PBS solution. Biosensors were found to be stable for up to two weeks at-20°C and to withstand sterilisation. Sensitivity was retained after application for 6 hours in vivo. Proofof-concept results are presented showing that penicillin concentrations measured using the microneedle-based biosensor track those measured using both discrete blood and microdialysis sampling in vivo. These preliminary results show the potential of this microneedle-based biosensor to provide a minimally-invasive means to measure real-time β-lactam concentrations in vivo, representing an important first step towards a closed-loop therapeutic drug monitoring system.
This paper evaluates the chemical stability of four arsenosugars using tetramethylammonium hydroxide (TMAOH) as an extraction solvent. This solvent was chosen because of the near quantitative removal of these arsenicals from difficult to extract seafood (oysters and shellfish). Four arsenosugars (3-[5'-deoxy-5'-(dimethylarsinoyl)-beta-ribofuranosyloxy]-2-hydroxypropylene glycol--As(328), 3-5'-deoxy-5'-(dimethylarsinoyl)-beta-ribofuranosyloxy]-2-hydroxypropanesulfonic acid--As(392), 3-[5'-deoxy-5'-(dimethylarsinoyl)-beta-ribofuranosyloxy]-2-hydroxypropyl hydrogen sulfate--As(408), and 3-[5'-deoxy-5'-(dimethylarsinoyl)-beta-ribofuranosyloxy]-2-hydroxypropyl-2,3-hydroxypropyl phosphate--As(482)) were evaluated. The stability of these four arsenosugars were studied independently in a solution of 2.5% TMAOH at 60 degrees C over a period of up to 8 h. Two arsenosugars, As(328) and As(392), were found to be relatively stable in this solution for up to 8 h. However, As(408) and As(482) formed detectable quantities of dimethylarsinic acid (DMAA) and As(328) within 0.5 and 2 h, respectively. It was found that 97% of As(408) degrades after 8 h of treatment producing 3.4 times as much DMAA as As(328). This is contrary to As(482), which produces 13 times as much As(328) as DMAA and only 37% of the As(482) was converted by the 8 h treatment at 60 degrees C. These degradation products led to the investigation of weaker TMAOH extraction solvents. Three different concentrations (2.5%, 0.83% and 0.25%) were used to determine the effect of TMAOH concentration on the degradation rate of As(408). By reducing the TMAOH concentration to 0.83%, the conversion of the arsenosugar to As(328) and DMAA is nearly eliminated (less than 5% loss). Arsenosugars, As(408) and As(482), were also studied in 253 mM NaOH to verify the degradation products. The NaOH experiments were conducted to investigate a possible hydroxide based reaction mechanism. Similar degradation plots were found for each arsenosugar when compared to the 2.5% TMAOH data. A mechanism has been proposed for the formation of As(328) from As(408) and As(482) in base via an SN2 reaction (hydroxide attack) at the side chain carbon adjacent to the inorganic ester. The formation of DMAA is observed in all arsenosugars after prolonged exposure. This probably occurs via an SN2 attack at the arsenic atom.
IntroductionDetermination of blood lactate levels supports decision-making in a range of medical conditions. Invasive blood-sampling and laboratory access are often required, and measurements provide a static profile at each instance. We conducted a phase I clinical study validating performance of a microneedle patch for minimally invasive, continuous lactate measurement in healthy volunteers.MethodsFive healthy adult participants wore a solid microneedle biosensor patch on their forearms and undertook aerobic exercise for 30 min. The microneedle biosensor quantifies lactate concentrations in interstitial fluid within the dermis continuously and in real-time. Outputs were captured as sensor current and compared with lactate concentrations from venous blood and microdialysis.ResultsThe biosensor was well-tolerated. Participants generated a median peak venous lactate of 9.25 mmol/L (IQR 6.73–10.71). Microdialysate concentrations of lactate closely correlated with blood. Microneedle biosensor current followed venous lactate concentrations and dynamics, with good agreement seen in all participants. There was an estimated lag-time of 5 min (IQR −4 to 11 min) between microneedle and blood lactate measurements.ConclusionThis study provides first-in-human data on use of a minimally invasive microneedle patch for continuous lactate measurement, providing dynamic monitoring. This low-cost platform offers distinct advantages to frequent blood sampling in a wide range of clinical settings, especially where access to laboratory services is limited or blood sampling is infeasible. Implementation of this technology in healthcare settings could support personalised decision-making in a variety of hospital and community settings.Trial registration numberNCT04238611.
A paucity of data describing citizen perceptions of novel technologies, including those containing unsupervised computer-controlled systems is currently available. We explored citizen perceptions of using a microneedle biosensor and automated dose control system at a university public festival. Groups of citizens (from 2-6 people per group) attended a short demonstration of a microneedle biosensor and automated dosing system versus a traditional phlebotomy approach over a two-day public festival. Individual groups discussed and reached consensus on a number of short questions regarding their perceptions on the acceptability of such technology. Over the two days, 100 groups participated (56/100 day 1 and 44/100 day 2). The majority of individuals reported high acceptability of microneedle technology (median Likert score 9/10), but the majority believed that doctors should decide what dose of antibiotic is delivered (75/100; 75%). Groups concurred with the acceptability of microneedles to reduce blood tests and pain associated with them. However, concerns were reported over unsupervised computer-controlled programmes making decision about antibiotic dosing. This was driven by concerns over computer error and the inability of systems to contextualise decision making to the human and social context. Future work must consider the greater role of citizen engagement in the development of such technologies, to ensure their acceptability upon implementation in clinical practice.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
customersupport@researchsolutions.com
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
This site is protected by reCAPTCHA and the Google Privacy Policy and Terms of Service apply.
Copyright © 2024 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.