The purpose of this study was to analyze the validity, reliability, and accuracy of new wearable and smartphone-based technology for the measurement of barbell velocity in resistance training exercises. To do this, 10 highly trained powerlifters (age = 26.1 ± 3.9 years) performed 11 repetitions with loads ranging 50–100% of the 1-Repetition maximum in the bench-press, full-squat, and hip-thrust exercises while barbell velocity was simultaneously measured using a linear transducer (LT), two Beast wearable devices (one placed on the subjects' wrist –BW–, and the other one directly attached to the barbell –BB–) and the iOS PowerLift app. Results showed a high correlation between the LT and BW (r = 0.94–0.98, SEE = 0.04–0.07 m•s−1), BB (r = 0.97–0.98, SEE = 0.04–0.05 m•s−1), and the PowerLift app (r = 0.97–0.98, SEE = 0.03–0.05 m•s−1) for the measurement of barbell velocity in the three exercises. Paired samples T-test revealed systematic biases between the LT and BW, BB and the app in the hip-thrust, between the LT and BW in the full-squat and between the LT and BB in the bench-press exercise (p < 0.001). Moreover, the analysis of the linear regression on the Bland-Altman plots showed that the differences between the LT and BW (R2 = 0.004–0.03), BB (R2 = 0.007–0.01), and the app (R2 = 0.001–0.03) were similar across the whole range of velocities analyzed. Finally, the reliability of the BW (ICC = 0.910–0.988), BB (ICC = 0.922–0.990), and the app (ICC = 0.928–0.989) for the measurement of the two repetitions performed with each load were almost the same than that observed with the LT (ICC = 0.937–0.990). Both the Beast wearable device and the PowerLift app were highly valid, reliable, and accurate for the measurement of barbell velocity in the bench-press, full-squat, and hip-thrust exercises. These results could have potential practical applications for strength and conditioning coaches who wish to measure barbell velocity during resistance training.
The purpose of this study was to analyse the validity and reliability of a novel iPhone app (named: PowerLift) for the measurement of mean velocity on the bench-press exercise. Additionally, the accuracy of the estimation of the 1-Repetition maximum (1RM) using the load-velocity relationship was tested. To do this, 10 powerlifters (Mean (SD): age = 26.5 ± 6.5 years; bench press 1RM · kg = 1.34 ± 0.25) completed an incremental test on the bench-press exercise with 5 different loads (75-100% 1RM), while the mean velocity of the barbell was registered using a linear transducer (LT) and Powerlift. Results showed a very high correlation between the LT and the app (r = 0.94, SEE = 0.028 m · s) for the measurement of mean velocity. Bland-Altman plots (R = 0.011) and intraclass correlation coefficient (ICC = 0.965) revealed a very high agreement between both devices. A systematic bias by which the app registered slightly higher values than the LT (P < 0.05; mean difference (SD) between instruments = 0.008 ± 0.03 m · s). Finally, actual and estimated 1RM using the app were highly correlated (r = 0.98, mean difference (SD) = 5.5 ± 9.6 kg, P < 0.05). The app was found to be highly valid and reliable in comparison with a LT. These findings could have valuable practical applications for strength and conditioning coaches who wish to measure barbell velocity in the bench-press exercise.
The very high load-velocity, force-velocity, and power-velocity relationships enables estimation of 1-RM by measuring movement velocity, as well as determination of maximal force, velocity, and power capabilities. This information could be of great interest to strength and conditioning coaches who wish to monitor pull-up performance.
Balsalobre-Fernández, C, Muñoz-López, M, Marchante, D, and García-Ramos, A. Repetitions in reserve and rate of perceived exertion increase the prediction capabilities of the load-velocity relationship. J Strength Cond Res 35(3): 724–730, 2021—This study aimed to (a) analyze the relationships between relative load (i.e., %1 repetition maximum; 1RM) and movement velocity, repetitions in reserve (RIR) and rate of perceived exertion (RPE) in competitive powerlifters and (b) examine whether a multiple linear regression model with the movement velocity, RIR, and RPE as predictor variables could improve the goodness of fit of the load-velocity relationship. Ten competitive powerlifters performed an incremental loading test (from 50 to 100% 1RM) on the full-squat, hip-thrust, and bench press exercises. Barbell velocity was measured using a linear position transducer, while RIR and RPE were registered immediately after each set. Velocity (r 2: 0.747–0.887), RIR (r 2: 0.857–0.928), and RPE (r 2: 0.908–0.933) were moderately to highly related to relative load. A higher amount of variance of the relative load was explained when the RIR and RPE were added to velocity in a multiple regression model in comparison with the load-velocity relationship (r 2: 0.924–0.947). Moreover, it was observed that, in all cases, individual load-velocity, load-RIR, and load-RPE relationships had higher r 2 scores than the generalized load-velocity relationship. Incorporating the RIR and RPE as predictors of the relative load along with movement velocity into a multiple linear regression was shown to provide better estimations of the %1RM than using a linear load-velocity relationship.
Hernández-Preciado, JA, Baz, E, Balsalobre-Fernández, C, Marchante, D, and Santos-Concejero, J. Potentiation effects of the French contrast method on the vertical jumping ability. J Strength Cond Res 32(7): 1909-1914, 2018-This study examined the acute effects of the potentiation protocol known as French Contrast Method on the vertical jumping ability measured using a countermovement jump (CMJ). Thirty-one athletes participated in this study (intervention group n = 17 and control group n = 14). The CMJ height was measured using the iOS application My Jump 2.0 before and after the French Contrast protocol, which consisted of 3 sets of isometric partial squats, drop jumps, dynamic half-squats, and hurdle jumps. The CMJ height improved from its baseline values by 5.1 ± 1.1% (p < 0.001, effect size [ES] = 0.27) after the first set, by 6.8 ± 1.8% (p < 0.001, ES = 0.41) after the second set, and by 8.5 ± 2.9% (p < 0.001, ES = 0.44) after the third set. The maximal potentiation value was an increase of 11 ± 6.3% (p < 0.001). The control group decreased its CMJ height from the baseline levels, reaching a significant decrement of -2.1 ± 1.6% (p = 0.047). These findings suggest that the French Contrast Method is a valid strategy to improve the vertical jumping ability. This method can be used after the warm-up as a conditioning activity to acutely enhance the lower body's force and power production.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
customersupport@researchsolutions.com
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
This site is protected by reCAPTCHA and the Google Privacy Policy and Terms of Service apply.
Copyright © 2024 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.