Background/AimsAcanthamoeba keratitis (AK) is a rare but sight-threatening infection. Molecular diagnosis of corneal scraping has improved the diagnosis of AK. Different molecular targets and conditions have been used in diagnosis thus far. In this study, we prospectively compared the performance of five PCR assays on corneal samples for the diagnosis of AK.Methods1217 corneal scraping samples were obtained from patients, for whom an AK was suspected. Sample processing involved both molecular diagnostics and culture. Acanthamoeba PCR assays detected different regions of the Acanthamoeba nuclear small-subunit rRNA gene: three final point PCR assays using Nelson, ACARNA and JDP1–JDP2 pairs of primers, and two real-time PCR assays using Acant primer-probe. Human DNA and internal control were co-amplified in the real-time PCR assay to ensure scraping quality and the absence of inhibitors. In the absence of a gold standard, the performance of each test was evaluated using latent class analysis. Genotypes of Acanthamoeba isolates were also characterised.ResultsEstimated prevalence of AK was 1.32%. The sensitivity of Acanthamoeba diagnostic PCRs (73.3% to 86.7%) did not differ significantly from that of culture (66.7%), or according to the target sequence or the technology. Sensitivity could be increased to 93.8% or 100% by combining two or three assays, respectively. PCR specificity (99.3% to 100%) differed between the assays. T4 was the predominant Acanthamoeba genotype (84.6%).ConclusionsCulture and a single PCR assay could lead to misdiagnosing AK. A combination of different PCR assays and improved sample quality could increase diagnosis sensitivity.
The OCTA seems to be a valuable tool in detecting myopic CNV with a high sensitivity. However, its specificity needs to be investigated in further studies.
Transient severe choroidal filling defects with subretinal exudation may be observed in idiopathic pulmonary arterial hypertension. The present case raised the questions of the triggering factor of the acute decompensation of the blood-retinal barrier and the cause of its spontaneous regression.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.