We explore the use of the recently proposed “total nuclear variation” (TVN) as a regularizer for reconstructing multi-channel, spectral CT images. This convex penalty is a natural extension of the total variation (TV) to vector-valued images and has the advantage of encouraging common edge locations and a shared gradient direction among image channels. We show how it can be incorporated into a general, data-constrained reconstruction framework and derive update equations based on the first-order, primal-dual algorithm of Chambolle and Pock. Early simulation studies based on the numerical XCAT phantom indicate that the inter-channel coupling introduced by the TVN leads to better preservation of image features at high levels of regularization, compared to independent, channel-by-channel TV reconstructions.
Objectives
The aim of this study was to develop a method for tracking respiratory motion throughout full MR or PET/MR studies that requires only minimal additional hardware and no modifications to the sequences.
Materials and Methods
Patient motion that is caused by respiration affects the quality of the signal of the individual radiofrequency receive coil elements. This effect can be detected as a modulation of a monofrequent signal that is emitted by a small portable transmitter placed inside the bore (Pilot Tone). The frequency is selected such that it is located outside of the frequency band of the actual MR readout experiment but well within the bandwidth of the radiofrequency receiver, that is, the oversampling area. Temporal variations of the detected signal indicate motion. After extraction of the signal from the raw data, principal component analysis was used to identify respiratory motion. The approach and potential applications during MR and PET/MR examinations that rely on a continuous respiratory signal were validated with an anthropomorphic, PET/MR-compatible motion phantom as well as in a volunteer study.
Results
Respiratory motion detection and correction were presented for MR and PET data in phantom and volunteer studies. The Pilot Tone successfully recovered the ground-truth respiratory signal provided by the phantom.
Conclusions
The presented method provides reliable respiratory motion tracking during arbitrary imaging sequences throughout a full PET/MR study. All results can directly be transferred to MR-only applications as well.
Purpose:
To develop a flexible method for tracking respiratory and cardiac motions throughout MR and PET-MR body examinations that requires no additional hardware and minimal sequence modification.
Methods:
The incorporation of a contrast-neutral rosette navigator module following the RF excitation allows for robust cardiorespiratory motion tracking with minimal impact on the host sequence. Spatial encoding gradients are applied to the FID signal and the desired motion signals are extracted with a blind source separation technique. This approach is validated with an anthropomorphic, PET-MR-compatible motion phantom as well as in 13 human subjects.
Results:
Both respiratory and cardiac motions were reliably extracted from the proposed rosette navigator in phantom and patient studies. In the phantom study, the MR-derived motion signals were additionally validated against the ground truth measurement of diaphragm displacement and left ventricle model triggering pulse.
Conclusion:
The proposed method yields accurate respiratory and cardiac motion-state tracking, requiring only a short (1.76 ms) additional navigator module, which is self-refocusing and imposes minimal constraints on sequence design.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.