e23575 Background: STS include a heterogeneous group of malignancies that arises from or into connective tissues and limbs are the preferential primary sites. An adequate local control with multimodality therapy can be obtained in most cases. An additional approach, that is, the IORT-LK is able to deliver high dose to risky areas for recurrence, minimizing the toxicity to structures around the target. Such an importance is even greater in abdominal sarcomas, because there is some difficulty in removing the whole neoplasia with clear margins. IORT-LK has the advantage of higher Relative Biological Effectiveness (RBE), a mathematical model that measures the potential for tumour double-strand break (radiation effectiveness), that is close to Proton beam and higher than electron beam. Nevertheless, IORT-LK is not free of complications. It has been reported peripheral neuropathy and enteritis, in cases of limb and abdominal STS, respectively. Methods: In this retrospective study from a single Brazilian institution (Hospital Alemão Oswaldo Cruz), we reported 6 patients with histologically confirmed STS, that underwent IORT-LK (Intrabeam - Carl Zeiss). There are 3 male and 3 female patients, with a median age 48 years, and mean of 39 years. The histological subtypes are as follows: fibromyxoid sarcoma, high grade pleomorphic sarcoma, desmoid tumor, chondrosarcoma, dedifferentiated liposarcoma and malignant schwannoma - one subtype for each patient. The primary sites are: inferior limb (3), superior limb (1) and abdomen (2). Results: IORT-LK was administered in doses that ranged from 14 to 15 Gy to the involved area. Two patients, each one with a limb STS, received also neoadjuvant chemotherapy. With a mean follow-up of 30 months, there is no local recurrence among the 6 patients reported. The first patient received the IORT-LK in April, 2017 and the last one in July, 2019. All of them had clinical observation up-to-dated on January, 2020. No serious complications were observed, but one patient had a moderate local infection. Conclusions: The therapy was well tolerated. We must emphasize that dose previously used by Brussiers was slightly superior than ours but with electrons and not Low-Kylovoltage. In his pilot study it was used 17 Gy for treatment of abdominal sarcomas. In sum, we believe that IORT-LK has higher RBE than previous available equipment and can improve local control of STS, mainly those that arise on the extremities. Future studies must be carried out to confirm our initial impression.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
customersupport@researchsolutions.com
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
This site is protected by reCAPTCHA and the Google Privacy Policy and Terms of Service apply.
Copyright © 2024 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.