Storage tank is an essential vessel in petrochemical industry, and the corrosion of tank is an important reason for the safety hazard. The corrosion of tank bottom plate is more serious than the tank wall, and it is not easy to check and repair, when damaged to a certain extent it will cause the leakage of the media, then lead to waste of energy, environmental pollution, at the same time it will cause a major accident. Magnetic flux leakage testing is widely used in the field of tank floor inspection with the advantages of fast scanning speed, accurate results and so on. In this paper, the finite element simulation and analysis of the corrosion defect leakage magnetic field is used to obtain the data, and the characteristic of the leakage magnetic field is extracted. The effect of defect depth and width and shape on the magnetic flux leakage field is studied, and the distribution curve of the magnetic flux leakage field is obtained.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.