In this patient subset, life-threatening arrhythmias and multiple electrophysiologic mechanisms are commonly encountered during RFA. Mild DOTR and a BSA < or = 1.7 m2 predict a higher acute success rate. While acute success rates are relatively high, recurrence is frequent.
A small percentage of pediatric patients with neurally mediated syncope will have an asystolic response during upright tilt table testing. The purpose of this study is to evaluate the incidence of asystole during tilt table testing, and to assess the outcome of medical management of such patients. Of 398 patients undergoing evaluation for recurrent syncope between January 1989 and 1994, 18 (4.5%) experienced asystole lasting > or = 5 seconds during baseline tilt test. Patients had experienced a mean of four episodes of syncope, with a mean age at the time of tilt test of 11.1 +/- 4.0 years. The median duration of asystole was 10 seconds (range 5-40 s). Treatment was individualized to increased fluids and salt intake (3 patients), metoprolol (8 patients), pseudoephedrine (4 patients), disopyramide (1 patient), or combination therapy with fludrohydrocortisone (2 patients). During a median duration of follow-up of 31 months, no additional syncope was experienced by 78% of patients. Recurrent syncope in 4 patients was associated with either noncompliance or discontinuation of therapy in 3 patients; in 1 patient, increasing the dose of metoprolol was effective in preventing recurrences. We conclude that young patients with recurrent syncope and asystole during tilt test may be safely and effectively managed with pharmacological therapy, without resorting to pacemaker implantation.
Permanent DCP is an effective therapy for selected pediatric patients with HOCM. Rapid atrial rates and intrinsic atrioventricular conduction, as well as congenital mitral valve abnormalities, may preclude effective pacing in certain patients.
Continued miniaturization of permanent pacing systems has promoted use of this technology in younger and smaller pediatric patients. Intermedics ThinLine 438-10 active fixation pacing leads (4.5 Fr lead body) were implanted in 26 patients (17 males/9 females; 9.9 +/- 6.9 years). Twenty of 26 patients received dual chamber systems, 6 of 26 patients single lead systems. Each patient has been followed 3 months. Pacemaker analysis at implant and 6 months later evaluated pulse width thresholds at 2.5 V (atrial 0.07 +/- 0.02 vs 0.13 +/- 0.02 ms [P = 0.01]; ventricular 0.08 +/- 0.04 ms vs 0.20 +/- 0.04 ms [P = 0.01]); sensing thresholds (atrial 4.1 +/- 0.41 mV vs 4.0 +/- 4.2 mV [P = NS]; ventricular 9.7 +/- 0.72 vs 9.3 +/- 0.94 mV [P = NS]); and impedance (atrial 345 +/- 12 vs 370 +/- 120 O [P = 0.04]; ventricular 412 +/- 17 vs 458 +/- 190 O [P < 0.01]). One volt lead failed with exit block at approximately 6 weeks. The youngest (9 months to 5 years) and smallest (6.5-18.0 kg) ten patients have each shown by venography to have at least mild venous stenosis at the lead(s) insertion site; five patients demonstrated collateral formation around asymptomatic obstruction, with no thrombus formation. The Intermedics 438-10 ThinLine pacing lead has demonstrated good and stable early postimplant electrical parameters. Angiographic evaluation in our smaller patients has shown evidence for asymptomatic venous obstruction.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.