A cross sectional survey was carried out on 138 workers exposed to laboratory animals. Sixty (44%) had symptoms in a self completed questionnaire that were consistent with laboratory animal allergy (LAA) of whom 15 (11%) had chest symptoms. There was a positive skin prick test to one or more animal urine extracts (rat, mouse, guinea pig, rabbit) in 13% and 38% had a positive radioallergosorbent test to urine extract. LAA chest symptoms were almost five times more common in atopic than non-atopic subjects (who were distinguished by skin test response to common, non-animal aeroallergens). A positive skin test to animal urine was associated with LAA chest symptoms and with atopy. Nose, eye, or skin symptoms without chest symptoms were not associated with atopy. There was an inverse relation between duration of employment at the firm and LAA chest symptoms, suggesting selection of affected people out of employment with animals.
More than 3600 white men, from 30 to 79 years old and without a history of myocardial infarction, underwent submaximal treadmill exercise tolerance tests as part of their baseline evaluation for the Lipid Research Clinics Mortality Follow-up Study. The exercise test was conducted according to a common protocol and coded centrally; depression of the ST segment by at least 1 mm (visual coding) and/or 10 microV-sec (ST integral, computer coding) signified a positive test. Concurrent measurements of age, blood pressure, history of cigarette smoking, and plasma levels of lipids, lipoproteins, and glucose, as well as other coronary risk factors, were obtained. Cumulative mortality from cardiovascular disease was 11.9% (22/185) over 8.1 years mean follow-up among men with a positive exercise test vs 1.2% (36/2993) over 8.6 years mean follow-up among men with a negative test. Three-quarters (43) of these deaths were due to coronary heart disease. The relative risk for cardiovascular mortality associated with a positive exercise test was 9.3 before and 4.6 after age adjustment. Cardiovascular mortality rates were especially elevated (relative risk 15.6 before and 5.1 after age adjustment) among the 82 men whose exercise tests were adjusted "strongly" positive based on degree and timing of the ischemic electrocardiographic response. A positive exercise test was also moderately associated with noncardiovascular mortality; the relative risk for all-cause mortality was 7.2 before and 3.4 after age adjustment. The relative risk for cardiovascular mortality associated with a positive exercise test was not appreciably altered by covariance adjustment for known coronary risk factors other than age. A positive exercise test was a stronger predictor of cardiovascular death than were high plasma levels of low-density lipoprotein cholesterol, low plasma levels of high-density lipoprotein cholesterol, smoking, hyperglycemia, or hypertension. Its impact on risk of cardiovascular death was equivalent to that of a 17.4 year increment in age.
Background:
The use of real-time continuous glucose monitoring (rtCGM) systems has proved to positively impact the management of type 1 diabetes with the potential to lower HbA1c, reduce frequency and time spent in hypoglycemia, and lower glycemic variability. Nevertheless, the acceptance of rtCGM remains below expectations and the dropout rate within the first year has been reported to be 27%. Besides financial reasons due to limited reimbursement, reasons include the need for frequent sensor replacement, the discomfort of wearing a sensor, the presence of adverse skin reactions, or privacy. Thus, novel approaches to rtCGM are desired to overcome these barriers. The first long-term implantable rtCGM system diversifies the field of glucose monitoring further. However, due to its novelty, there are no published clinical practice guidelines available.
Aims:
The aim of this article is to set the foundation for a best clinical practice for the everyday clinical care using a long-term implantable CGM system.
Methods:
An international expert panel for the long-term implantable CGM system developed this best practice guidance. All participants were certified and experienced in the use of the Eversense
®
long-term implantable CGM system. The workflows from the respective clinics were presented, discussed and are summarized in an ideal care workflow outlined in these practice recommendations.
Results:
The participants agreed on the following aspects: definition of the patient population that will benefit from a long-term implantable CGM device; real-world experience on safety and accuracy of a long-term CGM; definition of the ideal sensor position; description of the optimal process for sensor insertion, removal, and replacement.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.