Undoped and europium doped CaMoO4 and SrMoO4 scheelites are synthesized using a complex polymerization method. The phase purity of the sample is confirmed using powder X-ray diffraction (PXRD). X-ray photoelectron spectroscopy (XPS) was carried out to confirm the oxidation states of various constituents and dopant elements and also the presence of oxygen vacancies. Interestingly both CaMoO4 and SrMoO4 on irradiation with UV light give blue and green emission respectively. On europium doping, it was found that molybdate to Eu(3+) ion energy transfer is more efficient in SrMoO4:Eu compared to CaMoO4:Eu. It is also justified using a luminescence lifetime study which shows biexponential decay in the case of CaMoO4:Eu corresponding to both the host and europium ion; whereas a single lifetime is observed in the case of SrMoO4:Eu. Anomalies in host-dopant energy transfer are suitably explained using density functional theory (DFT) calculations and XPS. The actual site symmetry for the europium ion in CaMoO4 and SrMoO4 was also evaluated based on a Stark splitting pattern which turns out to be D2 and C2v respectively although it is S4 for Ca/Ba(2+) in AMoO4. This is also reflected in higher Ω2 values for SrMoO4:Eu than CaMoO4:Eu.
Metallic ruthenium nanoparticles (Ru NPs) are formed on the glassy carbon electrode (GC) at electrodeposition potential of -0.75 V, as observed from X-ray photoelectron spectroscopy. Thus formed Ru NPs have the arsenite selective surface and conducting core that is ideally suited for designing a highly sensitive and reproducible response generating matrix for the arsenite detection at an ultratrace concentration in aqueous matrices. Contrary to this, arsenate ions sorb via chemical interactions on the ruthenium oxide (RuO2 and RuO3) NPs formed at -0.25 V, but not on the Ru NPs. For exploring a possibility of the quantification of arsenite in the ultratrace concentration range, the Ru NPs have been deposited on the GC by a potentiostatic pulse method of electrodeposition at optimized -0.75 V for 1000 s. Arsenite preconcentrates onto the Ru surface just by dipping the RuNPs/GC into the arsenite solution as it interacts chemically with Ru NPs. Electrochemical impedance spectroscopy of As(III) loaded RuNPs/GC shows a linear increase in the charge transfer resistance with an increase in As(III) conc. Using a differential pulse voltammetric technique, arsenite is oxidized to arsenate leading to its quantitative determination without any interference of Cu(2+) ions that are normally encountered in the water systems. Thus, the use of RuNPs/GC eliminates the need for a preconcentration step in stripping voltammetry, which requires optimization of the parameters like preconcentration potential, time, stirring, inferences, and so on. The RuNPs/GC based differential pulse voltammetric (DPV) technique can determine the concentration of arsenite in a few min with a detection limit of 0.1 ppb and 5.4% reproducibility. The sensitivity of 2.38 nA ppb(-1) obtained in the present work for As(III) quantification is considerably better than that reported in the literature, with a similar detection limit and mild conditions (pH = 2). The RuNPs/GC based DPV has been evaluated for its analytical performance using the lake water, ground water, and seawater samples spiked with known amounts of As(III).
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.